Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range | |
Process connection | threaded connection G 1/2 DN15 flat seal |
Application |
---|
Special feature | Gold-plated contacts |
Application | totaliser function; for industrial applications |
Installation | connection to pipe by means of an adapter |
Media | conductive liquids; water; hydrous media |
Note on media | conductivity: ≥ 20 µS/cm | viscosity: < 70 mm²/s (40 °C) |
|
Medium temperature [°F] | 14…158 |
Pressure rating [bar] | 16 |
Pressure rating [psi] | 232 |
MAWP (for applications according to CRN) [bar] | 17.7 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | 95; (24 V) |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 5 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs |
---|
Inputs | counter reset |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 200 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (scalable) |
Max. load [Ω] | 500 |
Analogue voltage output [V] | 0…10; (scalable) |
Min. load resistance [Ω] | 2000 |
Pulse output | flow rate meter |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | |
Display range | -475.5…475.5 gph | -7.925…7.925 gpm |
|
Resolution | |
Set point SP | 3.5…396.5 gph | 0.06…6.6 gpm |
|
Reset point rP | 1.5…394 gph | 0.03…6.57 gpm |
|
Analogue start point ASP | |
Analogue end point AEP | |
In steps of | |
Volumetric flow quantity monitoring |
---|
Pulse value | 0.01…30 000 000 gal |
Pulse length [s] | 0,01…2 |
Temperature monitoring |
---|
Measuring range [°F] | -4…176 |
Resolution [°F] | 0.1 |
Set point SP [°F] | -2.5…176 |
Reset point rP [°F] | -3.5…175 |
Analogue start point [°F] | -4…140.5 |
Analogue end point [°F] | 31.5…176 |
In steps of [°F] | 0.5 |
Accuracy / deviations |
---|
Flow monitoring |
---|
Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
Repeatability | ± 0,2% MEW |
Temperature monitoring |
---|
Accuracy [K] | ± 4,5 (Q > 0,26 gpm) |
Response times |
---|
Flow monitoring |
---|
Response time [s] | 0.15; (dAP = 0, T19) |
Delay time programmable dS, dr [s] | 0…50 |
Damping for the switching output dAP [s] | 0…5 |
Temperature monitoring |
---|
Dynamic response T05 / T09 [s] | T09 = 20 (Q > 0,26 gpm) |
Software / programming |
---|
Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 3 |
Process data binary | 2 |
Min. process cycle time [ms] | 5 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 570 |
|
Operating conditions |
---|
Ambient temperature [°F] | 14…140 |
Storage temperature [°F] | -13…176 |
Protection | IP 67 |
Mechanical data |
---|
Weight [g] | 546 |
Materials | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK; FKM |
Process connection | threaded connection G 1/2 DN15 flat seal |
Displays / operating elements |
---|
Display | Display unit | 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) | switching status | 2 x LED, yellow | measured values | alphanumeric display, 4-digit | programming | alphanumeric display, 4-digit |
|
Remarks |
---|
Remarks | MW = measured value | MEW = Final value of the measuring range |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |