| Product characteristics | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Measuring range |  | 
| Process connection | threaded connection 1 1/2″ NPT DN40 | 
| Application | 
|---|
| Special feature | Gold-plated contacts | 
| Application | totaliser function; empty pipe detection; for industrial applications | 
| Media | conductive liquids; water; hydrous media | 
| Note on media | | conductivity: ≥ 20 µS/cm |  | viscosity: < 70 mm²/s (40 °C) | 
 | 
| Medium temperature [°F] | 14…158 | 
| Pressure rating [bar] | 16 | 
| MAWP (for applications according to CRN) [bar] | 16.5 | 
| Electrical data | 
|---|
| Operating voltage [V] | 18…32 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA] | < 150 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time [s] | 5 | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Inputs | 
|---|
| Inputs | counter reset | 
| Outputs | 
|---|
| Total number of outputs | 2 | 
| Output signal | switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) | 
| Electrical design | PNP/NPN | 
| Number of digital outputs | 2 | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V] | 2 | 
| Permanent current rating of switching output DC [mA] | 250; (per output) | 
| Number of analogue outputs | 1 | 
| Analogue current output [mA] | 4…20; (scalable) | 
| Max. load [Ω] | 500 | 
| Analogue voltage output [V] | 0…10; (scalable) | 
| Min. load resistance [Ω] | 2000 | 
| Pulse output | flow rate meter | 
| Short-circuit protection | yes | 
| Type of short-circuit protection | pulsed | 
| Overload protection | yes | 
| Frequency of the output [Hz] | 0.1…10000 | 
| Measuring/setting range | 
|---|
| Measuring range |  | 
| Display range | | -5760…5760 gph | -96…96 gpm | 
 | 
| Resolution |  | 
| Set point SP |  | 
| Reset point rP |  | 
| Analogue start point ASP |  | 
| Analogue end point AEP |  | 
| Low flow cut-off LFC |  | 
| In steps of |  | 
| Measuring dynamics | 1:60 | 
| Volumetric flow quantity monitoring | 
|---|
| Pulse value | 0.02…80 E06 gal | 
| In steps of | 0.02 gal | 
| Pulse length [s] | 0,016…2 | 
| Temperature monitoring | 
|---|
| Measuring range [°F] | -4…176 | 
| Display range [°F] | -40…212 | 
| Resolution [°F] | 0.5 | 
| Set point SP [°F] | -2…176 | 
| Reset point rP [°F] | -3…175 | 
| Analogue start point [°F] | -4…140 | 
| Analogue end point [°F] | 32…176 | 
| In steps of [°F] | 0.5 | 
| Accuracy / deviations | 
|---|
| Flow monitoring | 
|---|
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) | 
| Repeatability | ± 0,2% MEW | 
| Temperature monitoring | 
|---|
| Temperature drift | ± 0,0185 °F / K | 
| Accuracy [K] | ± 1 (77 °F; Q > 4 gpm) | 
| Response times | 
|---|
| Flow monitoring | 
|---|
| Response time [s] | 0.35; (dAP = 0) | 
| Delay time programmable dS, dr [s] | 0…50 | 
| Damping for the switching output dAP [s] | 0…5 | 
| Temperature monitoring | 
|---|
| Dynamic response T05 / T09 [s] | T09 = 3 (Q > 4 gpm) | 
| Software / programming | 
|---|
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection | 
| Interfaces | 
|---|
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.1 | 
| SDCI standard | IEC 61131-9 CDV | 
| Profiles | Smart Sensor: Process Data Variable; Device Identification | 
| SIO mode | yes | 
| Required master port type | A | 
| Process data analogue | 3 | 
| Process data binary | 2 | 
| Min. process cycle time [ms] | 5 | 
| Supported DeviceIDs | | Type of operation | DeviceID |  | Default | 392 | 
 | 
| Operating conditions | 
|---|
| Ambient temperature [°F] | 14…140 | 
| Storage temperature [°F] | -13…176 | 
| Protection | IP 65; IP 67 | 
| Mechanical data | 
|---|
| Weight [g] | 2755.95 | 
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | 
| Materials (wetted parts) | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM | 
| Process connection | threaded connection 1 1/2″ NPT DN40 | 
| Displays / operating elements | 
|---|
| Display | | Display unit | 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) |  | switching status | 2 x LED, yellow |  | measured values | alphanumeric display, 4-digit |  | programming | alphanumeric display, 4-digit | 
 | 
| Accessories | 
|---|
| Accessories (supplied) |  | 
| Remarks | 
|---|
| Remarks | | MW = measured value |  | MEW = Final value of the measuring range | 
 | 
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |