| Product characteristics | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Measuring range |  | 
| Process connection | threaded connection G 3/4 flat seal | 
| Application | 
|---|
| Special feature | Gold-plated contacts | 
| Application | totaliser function; for industrial applications | 
| Installation | connection to pipe by means of an adapter | 
| Media | water; glycol solutions; coolants; oil | 
| Note on media | | low-viscosity oils with viscosity: 7…40 mm²/s (40 °C) |  | high-viscosity oils with viscosity: 30…68 mm²/s (40 °C) | 
 | 
| Medium temperature [°C] | -10…80 | 
| Pressure rating [bar] | 16 | 
| Pressure rating [Mpa] | 1.6 | 
| Electrical data | 
|---|
| Operating voltage [V] | 19…30 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA] | 100 | 
| Min. insulation resistance [MΩ] | 100; (500 V DC) | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time [s] | 10 | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Inputs | 
|---|
| Inputs | counter reset | 
| Outputs | 
|---|
| Total number of outputs | 2 | 
| Output signal | switching signal; analogue signal; pulse signal; (configurable) | 
| Electrical design | PNP/NPN | 
| Number of digital outputs | 2 | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V] | 2 | 
| Permanent current rating of switching output DC [mA] | 250; (per output) | 
| Number of analogue outputs | 1 | 
| Analogue current output [mA] | 4…20; (scalable) | 
| Max. load [Ω] | 500 | 
| Analogue voltage output [V] | 0…10; (scalable) | 
| Min. load resistance [Ω] | 2000 | 
| Pulse output | flow rate meter | 
| Short-circuit protection | yes | 
| Type of short-circuit protection | pulsed | 
| Overload protection | yes | 
| Measuring/setting range | 
|---|
| Measuring range |  | 
| Display range |  | 
| Resolution |  | 
| Set point SP | | 0.1…50 l/min | 0.005…3 m³/h | 
 | 
| Reset point rP | | 0…49.9 l/min | 0…2.995 m³/h | 
 | 
| Analogue start point ASP |  | 
| Analogue end point AEP |  | 
| Max. flow rate |  | 
| In steps of |  | 
| Volumetric flow quantity monitoring | 
|---|
| Pulse value | 0.1 l…1 000 000 m³ | 
| Pulse length [s] | 0,05…2 | 
| Temperature monitoring | 
|---|
| Measuring range [°C] | -10…80 | 
| Resolution [°C] | 0.2 | 
| Set point SP [°C] | -9.8…80 | 
| Reset point rP [°C] | -10…79.8 | 
| Analogue start point [°C] | -10…62 | 
| Analogue end point [°C] | 8…80 | 
| In steps of [°C] | 0.2 | 
| Accuracy / deviations | 
|---|
| Flow monitoring | 
|---|
| Accuracy (in the measuring range) | < ± (3 % MW + 0,2 % MEW) / < ± (5 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) | 
| Repeatability | 0,1 l/min; 6 l/h; 0,006 m³/h | 
| Temperature monitoring | 
|---|
| Accuracy [K] | ± 3 (Q > 1 l/min) | 
| Response times | 
|---|
| Flow monitoring | 
|---|
| Response time [s] | 0.25; (dAP = 0) | 
| Delay time programmable dS, dr [s] | 0…50 | 
| Damping for the switching output dAP [s] | 0…1 | 
| Temperature monitoring | 
|---|
| Dynamic response T05 / T09 [s] | T09 = 70 (Q > 5 l/min); (water) | 
| Software / programming | 
|---|
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | -10…60 | 
| Storage temperature [°C] | -25…80 | 
| Protection | IP 67 | 
| Mechanical data | 
|---|
| Weight [g] | 1551.5 | 
| Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA | 
| Materials (wetted parts) | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 | 
| Process connection | threaded connection G 3/4 flat seal | 
| Displays / operating elements | 
|---|
| Display | | Display unit | 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) |  | switching status | 2 x LED, yellow |  | measured values | alphanumeric display, 4-digit |  | programming | alphanumeric display, 4-digit | 
 | 
| Accessories | 
|---|
| Accessories (supplied) |  | 
| Accessories (optional) | | adapter for pipe: 1 x R1/2, stainless steel, E40178 |  | adapter for pipe: 1 x R1/2, brass, E40151 | 
 | 
| Remarks | 
|---|
| Remarks | | MW = measured value |  | MEW = Final value of the measuring range |  | sealing: only with supplied Centellen seals | 
 | 
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |