Product characteristics |
---|
Number of inputs and outputs | Number of analogue outputs: 2 |
Measuring range | |
Process connection | threaded connection G 1 1/4 flat seal |
Application |
---|
Special feature | Gold-plated contacts |
Application | for industrial applications |
Installation | connection to pipe by means of an adapter |
Media | water; glycol solutions; coolants; oil |
Note on media | low-viscosity oils with viscosity: 7…40 mm²/s (40 °C) | high-viscosity oils with viscosity: 30…68 mm²/s (40 °C) |
|
Medium temperature [°C] | -10…80 |
Pressure rating [bar] | 16 |
Pressure rating [Mpa] | 1.6 |
Electrical data |
---|
Operating voltage [V] | 19…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | 100 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 10 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of analogue outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | analogue signal |
Number of analogue outputs | 2 |
Analogue current output [mA] | 4…20; (scalable) |
Max. load [Ω] | 500 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | |
Display range | |
Resolution | |
Analogue start point ASP | |
Analogue end point AEP | 40…200 l/min | 10.28…52.84 gpm |
|
Max. flow rate [l/min] | 220 |
In steps of | |
Temperature monitoring |
---|
Measuring range [°C] | -10…80 |
Resolution [°C] | 0.2 |
Analogue start point [°C] | -10…62 |
Analogue end point [°C] | 8…80 |
In steps of [°C] | 0.2 |
Accuracy / deviations |
---|
Flow monitoring |
---|
Accuracy (in the measuring range) | < ± (3 % MW + 0,2 % MEW) / < ± (8 % MW + 0,5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) |
Repeatability | 1 l/min; 60 l/h; 0,05 gpm; 3 gph |
Temperature monitoring |
---|
Accuracy [K] | ± 3 (Q > 20 l/min) |
Response times |
---|
Flow monitoring |
---|
Response time [s] | 0.25; (dAP = 0) |
Damping for the switching output dAP [s] | 0…1 |
Temperature monitoring |
---|
Dynamic response T05 / T09 [s] | T09 = 30 (Q > 20 l/min); (water) |
Operating conditions |
---|
Ambient temperature [°C] | -10…60 |
Storage temperature [°C] | -25…80 |
Protection | IP 67 |
Mechanical data |
---|
Weight [g] | 1883 |
Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA |
Materials (wetted parts) | stainless steel (1.4404 / 316L); FKM; PPS; Centellen 200 |
Process connection | threaded connection G 1 1/4 flat seal |
Displays / operating elements |
---|
Display | Display unit | 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) | measured values | alphanumeric display, 4-digit | programming | alphanumeric display, 4-digit |
|
Display unit | l/min; m³/h; gpm; gph; °C; °F |
Accessories |
---|
Accessories (supplied) | |
Accessories (optional) | adapter for pipe: 1 x R 1, stainless steel, E40205 | adapter for pipe: 1 x 1″ NPT, stainless steel, E40206 |
|
Remarks |
---|
Remarks | sealing: only with supplied Centellen seals | MW = measured value | MEW = Final value of the measuring range |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |