|  Product characteristics | 
|---|
|  Number of inputs and outputs |  Number of analogue outputs: 1 | 
|  Measuring range |  | 
|  Process connection |  threaded connection G 1/4 external thread | 
|  Installation length EL [mm] |  200 | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Measuring element |  1 x Pt 1000; (to DIN EN 60751, class A) | 
|  Media |  liquids and gases | 
|  Pressure rating [bar] |  400 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  10…30 DC; (“supply class 2” to cULus) | 
|  Current consumption [mA] |  < 30 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of analogue outputs: 1 | 
|  Outputs | 
|---|
|  Total number of outputs |  1 | 
|  Output signal |  analogue signal | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20 | 
|  Max. load [Ω] |  (Ub – 8,5 V) / 21,5 mA; 24 V: 720 Ω | 
|  Short-circuit protection |  yes | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Measuring range |  | 
|  Resolution | 
|---|
|  Resolution of analogue output [K] |  0.04 | 
|  Accuracy / deviations | 
|---|
|  Precision analogue output [K] |  ± 0,3 + (± 0,1 % MS) | 
|  Temperature coefficient [% of the span / 10 K] |  0,1; (in case of deviation from the reference condition 25 ± 5 °C) | 
|  Response times | 
|---|
|  Dynamic response T05 / T09 [s] |  1 / 3; (to DIN EN 60751) | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -40…100 | 
|  Storage temperature [°C] |  -40…100 | 
|  Protection |  IP 68; IP 69K | 
|  Mechanical data | 
|---|
|  Weight [g] |  155.5 | 
|  Dimensions [mm] |  Ø 18.8 | 
|  Materials |  stainless steel (1.4404 / 316L); PEI; FKM | 
|  Materials (wetted parts) |  stainless steel (1.4404 / 316L); FKM | 
|  Process connection |  threaded connection G 1/4 external thread | 
|  Probe diameter [mm] |  6 | 
|  Installation length EL [mm] |  200 | 
|  Remarks | 
|---|
|  Remarks | |  The values for accuracy apply to flowing water. |  |  referring to UL: for use on a low voltage circuit with overcurrent protection |  |  in accordance with UL873 tab. 28.1 or Imax = 100/Ub (Ub = voltage of the circuit) |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |