| Product characteristics |
|---|
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Measuring range | |
| Process connection | threaded connection G 1/4 external thread |
| Installation length EL [mm] | 60 |
| Application |
|---|
| Special feature | Gold-plated contacts |
| Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) |
| Media | liquids and gases |
| Medium temperature | | < 150; (< 40 min) °C | < 302; (< 40 min) °F |
|
| Pressure rating [bar] | 400 |
| Minimum installation depth [mm] | 15 |
| Electrical data |
|---|
| Operating voltage [V] | 18…31.6 DC |
| Current consumption [mA] | < 25 |
| Protection class | III |
| Reverse polarity protection | yes |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of analogue outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 1 |
| Output signal | analogue signal |
| Electrical design | AS-i |
| Number of analogue outputs | 1 |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Probe length L [mm] | 60 |
| Measuring range | |
| Resolution |
|---|
| Resolution of analogue output [K] | 0.05 |
| Accuracy / deviations |
|---|
| Precision analogue output [K] | ± 0,1 (60°C / 140°F ) / ± 0,3 (0…140°C / 32…284°F) |
| Temperature coefficient [% of the span / 10 K] | < ± 0,1; (in case of deviation from the reference condition 25 ± 5 °C) |
| Response times |
|---|
| Dynamic response T05 / T09 [s] | 1 / 3; (to DIN EN 60751) |
| Operating conditions |
|---|
| Ambient temperature [°C] | -25…70 |
| Storage temperature [°C] | -40…100 |
| Protection | IP 68; IP 69K |
| AS-i classification |
|---|
| AS-i version | 2.11 |
| AS-i I/O configuration [hex] | 7 |
| AS-i ID code [hex] | 3.C |
| Mechanical data |
|---|
| Weight [g] | 169.5 |
| Dimensions [mm] | Ø 30 / L = 127.9 |
| Materials | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); PA |
| Materials (wetted parts) | stainless steel (1.4404 / 316L) |
| Process connection | threaded connection G 1/4 external thread |
| Installation length EL [mm] | 60 |
| Displays / operating elements |
|---|
| Display | | operation | 1 x LED, green | | failure | 1 x LED, red |
|
| Remarks |
|---|
| Remarks | | The values for accuracy apply to flowing water. | | referring to UL: for use on a low voltage circuit with overcurrent protection | | in accordance with UL873 tab. 28.1 or Imax = 100/Ub (Ub = voltage of the circuit) |
|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |