Product characteristics |
---|
Number of inputs and outputs | Number of analogue outputs: 1 |
Measuring range | |
Process connection | threaded connection G 1/2 external thread |
Installation length EL [mm] | 87.5 |
Application |
---|
Special feature | Gold-plated contacts |
Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) |
Media | liquids and gases |
Medium temperature | < 150; (< 40 min) °C | < 302; (< 40 min) °F |
|
Pressure rating [bar] | 300 |
Note on pressure rating | sensor | When mounted in adapters the specifications of the adapter data sheet apply. |
|
Minimum installation depth [mm] | 15 |
Electrical data |
---|
Operating voltage [V] | 18…31.6 DC |
Current consumption [mA] | < 25 |
Protection class | III |
Reverse polarity protection | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 1 |
Output signal | analogue signal |
Electrical design | AS-i |
Number of analogue outputs | 1 |
Overload protection | yes |
Measuring/setting range |
---|
Probe length L [mm] | 87.5 |
Measuring range | |
Resolution |
---|
Resolution of analogue output [K] | 0.05 |
Accuracy / deviations |
---|
Precision analogue output [K] | ± 0,1 (60°C / 140°F ) / ± 0,3 (0…140°C / 32…284°F) |
Temperature coefficient [% of the span / 10 K] | < ± 0,1; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times |
---|
Dynamic response T05 / T09 [s] | 1 / 3; (to DIN EN 60751) |
Operating conditions |
---|
Ambient temperature [°C] | -25…70 |
Storage temperature [°C] | -40…100 |
Protection | IP 68; IP 69K |
AS-i classification |
---|
AS-i version | 2.11 |
AS-i I/O configuration [hex] | 7 |
AS-i ID code [hex] | 3.C |
Mechanical data |
---|
Weight [g] | 258.5 |
Dimensions [mm] | Ø 30 / L = 190.5 |
Materials | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); PA |
Materials (wetted parts) | stainless steel (1.4404 / 316L) |
Tightening torque [Nm] | 30…50 |
Process connection | threaded connection G 1/2 external thread |
Installation length EL [mm] | 87.5 |
Displays / operating elements |
---|
Display | operation | 1 x LED, green | failure | 1 x LED, red |
|
Remarks |
---|
Remarks | The values for accuracy apply to flowing water. | referring to UL: for use on a low voltage circuit with overcurrent protection | in accordance with UL873 tab. 28.1 or Imax = 100/Ub (Ub = voltage of the circuit) |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |