|  Product characteristics | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 1; Number of analogue outputs: 1 | 
|  Measuring range |  | 
|  Process connection |  threaded connection G 1 external thread Aseptoflex Vario | 
|  Installation length EL [mm] |  50 | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Measuring element |  1 x Pt 1000 + 1 x NTC; (thermically coupled, with backup function (temperature measuring even if one element fails)) | 
|  Media |  liquids and gases | 
|  Pressure rating [bar] |  50 | 
|  Minimum installation depth [mm] |  25 | 
|  MAWP (for applications according to CRN) [bar] |  50 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…32 DC; (“supply class 2” to cULus) | 
|  Current consumption [mA] |  6; (24 V) | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  8 | 
|  Integrated watchdog |  yes | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 1; Number of analogue outputs: 1 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; analogue signal; IO-Link; (configurable) | 
|  Electrical design |  PNP/NPN | 
|  Number of digital outputs |  1 | 
|  Output function |  normally open / normally closed / diagnostic signal; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2 | 
|  Permanent current rating of switching output DC [mA] |  150; (200 (…60°C); 250 (…40 °C)) | 
|  Diagnostic output |  diagnostic output for drift and fault monitoring | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20 | 
|  Max. load [Ω] |  (Ub – 15 V) x 50 | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Measuring range |  | 
|  Note on measuring range |  | 
|  Factory setting |  0…150 °C / 32…302 °F | 
|  Drift warning |  | 
|  Drift alarm |  | 
|  In steps of |  | 
|  Resolution | 
|---|
|  Resolution of analogue output [K] |  0.05 | 
|  Accuracy / deviations | 
|---|
|  Precision analogue output [K] |  ± 0,2 (-10…130°C); ± 0,3 (130…140°C); ± 0,3 ± 0,1% MS (-25…-10/140…160°C); (probe completely inserted into the measured medium up to the sealing chamfer) | 
|  Temperature coefficient [% of the span / 10 K] |  < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) | 
|  Response times | 
|---|
|  Dynamic response T05 / T09 [s] |  3 / 6 | 
|  Software / programming | 
|---|
|  Parameter setting options |  drift warning/drift alarm threshold; Fail-Safe; Display unit; scaling of the analogue output; redundancy switching; performance diagnostic output; switching logic; normally open / normally closed | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM1 (4,8 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 CDV | 
|  Profiles |  Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  1 | 
|  Process data binary |  1 | 
|  Min. process cycle time [ms] |  18.8 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  323 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -25…70 | 
|  Storage temperature [°C] |  -40…85 | 
|  Protection |  IP 68; IP 69K | 
|  Mechanical data | 
|---|
|  Weight [g] |  402.5 | 
|  Materials |  stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L); PEI; FKM | 
|  Materials (wetted parts) |  stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L) | 
|  Process connection |  threaded connection G 1 external thread Aseptoflex Vario | 
|  Surface characteristics Ra/Rz of the wetted parts |  Ra: < 0.6 | 
|  Installation length EL [mm] |  50 | 
|  Remarks | 
|---|
|  Remarks |  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |