Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Measuring range | |
Process connection | threaded connection G 1/2 external thread |
Installation length EL [mm] | 87.5 |
Application |
---|
Special feature | Gold-plated contacts |
Measuring element | 1 x Pt 1000 + 1 x NTC; (thermically coupled, with backup function (temperature measuring even if one element fails)) |
Media | liquids and gases |
Pressure rating [bar] | 50 |
Minimum installation depth [mm] | 25 |
MAWP (for applications according to CRN) [bar] | 50 |
Electrical data |
---|
Operating voltage [V] | 18…32 DC; (“supply class 2” to cULus) |
Current consumption [mA] | 6; (24 V) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 8 |
Integrated watchdog | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 1 |
Output function | normally open / normally closed / diagnostic signal; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 150; (200 (…60°C); 250 (…40 °C)) |
Diagnostic output | diagnostic output for drift and fault monitoring |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20 |
Max. load [Ω] | (Ub – 15 V) x 50 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | |
Note on measuring range | |
Factory setting | 0…150 °C / 32…302 °F |
Drift warning | |
Drift alarm | |
In steps of | |
Resolution |
---|
Resolution of analogue output [K] | 0.05 |
Accuracy / deviations |
---|
Precision analogue output [K] | ± 0,2 (-10…130°C); ± 0,3 (130…140°C); ± 0,3 ± 0,1% MS (-25…-10/140…160°C); (probe completely inserted into the measured medium up to the sealing chamfer) |
Temperature coefficient [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times |
---|
Dynamic response T05 / T09 [s] | 3 / 6 |
Software / programming |
---|
Parameter setting options | drift warning/drift alarm threshold; Fail-Safe; Display unit; scaling of the analogue output; redundancy switching; performance diagnostic output; switching logic; normally open / normally closed |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM1 (4,8 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 CDV |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 1 |
Min. process cycle time [ms] | 18.8 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 323 |
|
Operating conditions |
---|
Ambient temperature [°C] | -25…70 |
Storage temperature [°C] | -40…85 |
Protection | IP 68; IP 69K |
Mechanical data |
---|
Weight [g] | 345 |
Materials | stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L); PEI; FKM |
Materials (wetted parts) | stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L) |
Tightening torque [Nm] | 30…50 |
Process connection | threaded connection G 1/2 external thread |
Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.6 |
Installation length EL [mm] | 87.5 |
Remarks |
---|
Remarks | |
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |