| Product characteristics | 
|---|
| Number of inputs and outputs | Number of analogue outputs: 1 | 
| Measuring range |  | 
| Process connection | Clamp DN25…DN40 (1…1,5″) DIN 32676 (ISO 2852) | 
| Installation length EL [mm] | 50 | 
| Application | 
|---|
| Measuring element | 1 x Pt 1000; (to DIN EN 60751, class A) | 
| Media | liquids and gases | 
| Pressure rating [bar] | 100 | 
| Vacuum resistance [mbar] | -1000 | 
| MAWP (for applications according to CRN) [bar] | 60 | 
| Electrical data | 
|---|
| Operating voltage [V] | 18…32 DC; (“supply class 2” to cULus) | 
| Current consumption [mA] | < 50 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time [s] | 2 | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of analogue outputs: 1 | 
| Outputs | 
|---|
| Total number of outputs | 1 | 
| Output signal | analogue signal; IO-Link; (configurable) | 
| Number of analogue outputs | 1 | 
| Analogue current output [mA] | 4…20 | 
| Max. load [Ω] | 300 | 
| Short-circuit protection | yes | 
| Overload protection | yes | 
| Measuring/setting range | 
|---|
| Measuring range |  | 
| Factory setting | 0…100 °C | 
| Resolution | 
|---|
| Resolution of analogue output [K] | 0.04 | 
| Resolution of display [K] | 0.1 | 
| Accuracy / deviations | 
|---|
| Precision analogue output [K] | ± 0,3 + (± 0,1 % MS) | 
| Temperature coefficient [% of the span / 10 K] | 0,1; (in case of deviation from the reference condition 25 °C) | 
| Response times | 
|---|
| Dynamic response T05 / T09 [s] | 1 / 3 | 
| Interfaces | 
|---|
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.1 | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | -25…80 | 
| Storage temperature [°C] | -40…100 | 
| Protection | IP 67; IP 68; IP 69K | 
| Mechanical data | 
|---|
| Weight [g] | 336.5 | 
| Materials | stainless steel (1.4404 / 316L); PEI; FKM | 
| Materials (wetted parts) | stainless steel (1.4404 / 316L) electropolished | 
| Process connection | Clamp DN25…DN40 (1…1,5″) DIN 32676 (ISO 2852) | 
| Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 | 
| Probe diameter [mm] | 6 | 
| Installation length EL [mm] | 50 | 
| Displays / operating elements | 
|---|
| Display | |  | 7-segment LED display, 4-digit |  |  | display unit / status, °C / °F | 
 | 
| Remarks | 
|---|
| Remarks | | MS = set measuring span |  | The values for accuracy apply to flowing water. | 
 | 
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x M12 |