|  Product characteristics | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 1; Number of analogue outputs: 1 | 
|  Measuring range |  | 
|  Application | 
|---|
|  Application |  asphalt; coated metal; liquids; glass; rubber; wood; ceramics; plastics; lacquers; food products; paper; fabric | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…32 DC; (to SELV/PELV) | 
|  Current consumption [mA] |  < 50 | 
|  Min. insulation resistance [MΩ] |  100; (50 V DC) | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  < 1 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 1; Number of analogue outputs: 1 | 
|  Inputs | 
|---|
|  Test input |  type 3 (IEC 61131-2) | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; analogue signal; IO-Link; (configurable) | 
|  Electrical design |  PNP | 
|  Number of digital outputs |  1 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2.5 | 
|  Permanent current rating of switching output DC [mA] |  150 | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20 | 
|  Max. load [Ω] |  500 | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Short-circuit proof |  yes | 
|  Overload protection |  yes | 
|  Detection zone | 
|---|
|  Wave length range [µm] |  8…14 | 
|  Measuring/setting range | 
|---|
|  Measuring range |  | 
|  Set point SP |  | 
|  Reset point rP |  | 
|  Analogue start point |  | 
|  Analogue end point |  | 
|  In steps of |  | 
|  Resolution | 
|---|
|  Resolution of switching output [K] |  0.5 | 
|  Resolution of analogue output [K] |  0.2; (+ 0.03% of the set measuring span) | 
|  Resolution of display [K] |  0.5 | 
|  Accuracy / deviations | 
|---|
|  Accuracy [K] |  < ± 1 %; (of measured value, min. 2 K (degree of emission = 1, T = 23 °C)) | 
|  Repeatability [K] |  1 | 
|  Response times | 
|---|
|  Response time [ms] |  100 | 
|  Software / programming | 
|---|
|  Adjustment of the switch point |  programming buttons | 
|  Parameter setting options |  analogue range; normally open / normally closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  16 | 
|  Process data binary |  1 | 
|  Min. process cycle time [ms] |  3.6 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  716 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  0…65 | 
|  Storage temperature [°C] |  -20…80 | 
|  Max. relative air humidity [%] |  95; (non condensing) | 
|  Protection |  IP 65 | 
|  Mechanical data | 
|---|
|  Weight [g] |  411.5 | 
|  Housing |  threaded type | 
|  Dimensions [mm] |  M30 x 1.5 | 
|  Thread designation |  M30 x 1.5 | 
|  Materials |  threaded sleeve: stainless steel (1.4305 / 303); polyester | 
|  Lens material | |  Infrared transparent crystal lens with anti-reflex coating |  
  | 
|  Displays / operating elements | 
|---|
|  Display | |  Display unit |  2 x LED, yellow |  |  switching status |  1 x LED, yellow |  |  function display |  7-segment LED display, 4-digit |  |  measured values |  7-segment LED display, 4-digit |  
  | 
|  Operating elements |  | 
|  Accessories | 
|---|
|  Accessories (supplied) |  | 
|  Remarks | 
|---|
|  Remarks | |  Use a screened cable to protect infrared temperature sensors from interference. |  |  The screen must be connected to the housing of the sensor via the connector. |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12 |