| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range | |
| Application |
|---|
| Application | tempering temperatures; glass melting; graphite; ceramics; metals; forging; sintering; heat treatment; rolling |
| Electrical data |
|---|
| Operating voltage [V] | 18…32 DC; (to SELV/PELV) |
| Current consumption [mA] | < 50 |
| Min. insulation resistance [MΩ] | 100; (50 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 1 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
| Inputs |
|---|
| Test input | type 3 (IEC 61131-2) |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 150 |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20 |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Short-circuit proof | yes |
| Overload protection | yes |
| Detection zone |
|---|
| Wave length range [µm] | 1…1.7 |
| Measuring/setting range |
|---|
| Measuring range | |
| Set point SP | |
| Reset point rP | |
| Analogue start point | |
| Analogue end point | |
| In steps of | |
| Resolution |
|---|
| Resolution of switching output [K] | 1 |
| Resolution of analogue output [K] | 0.2; (+ 0.03% of the set measuring span) |
| Resolution of display [K] | 1 |
| Accuracy / deviations |
|---|
| Accuracy [K] | < ± 0,5 %; (of measured value, min. 4 K (degree of emission = 1, T = 23 °C)) |
| Repeatability [K] | 1 |
| Response times |
|---|
| Response time [ms] | 2; (T > 600 °C) |
| Software / programming |
|---|
| Adjustment of the switch point | programming buttons |
| Parameter setting options | analogue range; normally open / normally closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 16 |
| Process data binary | 1 |
| Min. process cycle time [ms] | 3.6 |
| Supported DeviceIDs | | Type of operation | DeviceID | | Default | 717 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | 0…65 |
| Storage temperature [°C] | -20…80 |
| Max. relative air humidity [%] | 95; (non condensing) |
| Protection | IP 65 |
| Mechanical data |
|---|
| Weight [g] | 544 |
| Housing | threaded type |
| Dimensions [mm] | M30 x 1.5 / L = 239.5 |
| Thread designation | M30 x 1.5 |
| Materials | threaded sleeve: stainless steel (1.4305 / 303); polyester |
| Lens material | |
| Displays / operating elements |
|---|
| Display | | Display unit | 2 x LED, yellow | | switching status | 1 x LED, yellow | | function display | 7-segment LED display, 4-digit | | measured values | 7-segment LED display, 4-digit | | setting aid | LED pilot light, green |
|
| Operating elements | |
| Accessories |
|---|
| Accessories (supplied) | |
| Remarks |
|---|
| Remarks | | Use a screened cable to protect infrared temperature sensors from interference. | | The screen must be connected to the housing of the sensor via the connector. |
|
| Pack quantity | 1 pcs. |