|  Product characteristics | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 1; Number of analogue outputs: 1 | 
|  Measuring range [°C] |  -100…600 | 
|  Process connection |  threaded connection G 1/2 external thread | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Application |  for Pt100 and Pt1000 measuring elements | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…32 DC; (“supply class 2” to cULus) | 
|  Current consumption [mA] |  < 50 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  1 | 
|  Integrated watchdog |  yes | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 1; Number of analogue outputs: 1 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; analogue signal; IO-Link; (configurable) | 
|  Electrical design |  PNP/NPN | 
|  Number of digital outputs |  1 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2.5 | 
|  Permanent current rating of switching output DC [mA] |  250 | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20 | 
|  Max. load [Ω] |  500 | 
|  Analogue voltage output [V] |  0…10 | 
|  Min. load resistance [Ω] |  2000 | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Measuring range [°C] |  -100…600 | 
|  Factory setting |  -40…300 °C | 
|  Set point SP [°C] |  -99.8…600 | 
|  Reset point rP [°C] |  -100…599.8 | 
|  Analogue start point [°C] |  -100…595 | 
|  Analogue end point [°C] |  -95…600 | 
|  In steps of [°C] |  0.1 | 
|  Resolution | 
|---|
|  Resolution of switching output [K] |  0.1 | 
|  Resolution of analogue output [K] |  current output: MS / 4096; voltage output: MS / 3561 | 
|  Resolution of display [K] |  0.1 | 
|  Accuracy / deviations | 
|---|
|  Switch point accuracy [K] |  ± 0,3 + (± 0,1 % MS) | 
|  Precision analogue output [K] |  ± 0,3 + (± 0,1 % MS) | 
|  Display accuracy [K] |  ± 0,3 + (± 0,1 % MS) | 
|  Temperature coefficient [% of the span / 10 K] |  0,1; (in case of deviation from the reference condition 25 °C) | 
|  Response times | 
|---|
|  Response time [ms] |  390 | 
|  Max. response time analogue output [ms] |  390 | 
|  Software / programming | 
|---|
|  Parameter setting options |  hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; current/voltage output | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -25…80 | 
|  Storage temperature [°C] |  -40…100 | 
|  Protection |  IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  191 | 
|  Materials |  stainless steel (1.4301 / 304); EPDM/X; PC; PBT; FPM | 
|  Process connection |  threaded connection G 1/2 external thread | 
|  Displays / operating elements | 
|---|
|  Display | |  Display unit |  1 x LED, green |  |  switching status |  LED, yellow |  |  measured values |  alphanumeric display, red/green 4-digit |  
  | 
|  Remarks | 
|---|
|  Remarks |  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |