Product characteristics
Measuring range
4…100 l/min 0.24…6 m³/h 64…1586 gph 1.05…26.4 gpm
Process connection threaded connection G 1 1/2 internal thread
Application
Special feature Gold-plated contacts
Media Liquids; oil
Note on media
oil with viscosity: 320 mm²/s (40 °C)
Medium temperature [°C] -10…100
Pressure rating [bar] 63
Pressure rating [Mpa] 6.3
Note on pressure rating
at medium temperature >70°C: 50 bar / 5 MPa
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV; “supply class 2” to cULus)
Current consumption [mA] < 50
Protection class III
Reverse polarity protection yes
Power-on delay time [s] < 3
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; frequency signal; IO-Link
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Max. current load per output [mA] 150; (200: …60 °C; Ambient temperature; 250: …40 °C; Ambient temperature)
Analogue current output [mA] 4…20
Max. load [Ω] 500
Short-circuit protection yes
Overload protection yes
Frequency of the output [Hz] 0…10000
Measuring/setting range
Measuring range
4…100 l/min 0.24…6 m³/h 64…1586 gph 1.05…26.4 gpm
Display range
0…120 l/min 0…7.2 m³/h 0…1902 gph 0…31.7 gpm
Resolution
0.1 l/min 0.01 m³/h 1 gph 0.01 gpm
Set point SP
0.7…100 l/min 0.04…6 m³/h 10…1586 gph 0.15…26.4 gpm
Reset point rP
0…99.3 l/min 0…5.96 m³/h 0…1574 gph 0…26.25 gpm
Frequency end point, FEP
6.7…100 l/min 0.4…6 m³/h 106…1586 gph 1.75…26.4 gpm
In steps of
0.1 l/min 0.01 m³/h 2 gph 0.05 gpm
Frequency at the end point FRP [Hz] 10…10000
In steps of [Hz] 10
Measuring dynamics 1:50
In steps of 10 Hz
Temperature monitoring
Measuring range
-10…100 °C 14…212 °F
Display range
-32…122 °C -25.6…251.6 °F
Resolution
0.1 °C 0.1 °F
Set point SP
-9.3…100 °C 15.2…212 °F
Reset point rP
-10…99.3 °C 14…210.8 °F
In steps of
0.1 °C 0.2 °F
Frequency start point, FSP
-10…78 °C 14…172.4 °F
Frequency end point, FEP
12…100 °C 53.6…212 °F
Frequency at the end point FRP [Hz] 10…10000
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) ± 5 % MEW; (Q > 1 l/min; 20…70 °C Medium temperature)
Repeatability ± 1 % MEW
Temperature monitoring
Temperature drift 0,029 °C / K
Accuracy [K] 3 K (25°C; Q > 1 l/min)
Response times
Flow monitoring
Response time [s] 0.01
Damping for the switching output dAP [s] 0…5
In steps of [s] 0.1
Damping for the analogue output dAA [s] 0…5
In steps of [s] 0.1
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 120 (Q > 1 l/min)
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; current/frequency output; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour; calibration factor
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 2
Min. process cycle time [ms] 3.2
Supported DeviceIDs
Type of operation DeviceID
Default 1046
Operating conditions
Ambient temperature [°C] 0…60
Note on ambient temperature
medium temperature < 80 °C
medium temperature < 100 °C: 0…40 °C
Storage temperature [°C] -15…80
Protection IP 65; IP 67
Mechanical data
Weight [g] 2803.4
Materials stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Materials (wetted parts) stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Process connection threaded connection G 1 1/2 internal thread
Switching cycles mechanical 10 million
Displays / operating elements
Display
Display unit 6 x LED, green
switching status 2 x LED, yellow
measured values alphanumeric display, red/green alternating indication 4-digit
programming alphanumeric display, 4-digit
Remarks
Remarks
Recommendation: use a 200-micron filter.
All data refer to oil with the following nominal viscosity:
320 cSt, 40 °C ± 3 K
MW = measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; Contacts: gold-plated

Thông tin bổ sung

Thương hiệu
Thời gian bảo hành

5 Năm

Điện áp ngõ vào
Ngõ ra

Analog, NC, NO

Yêu cầu tư vấn0983 995 440(Call/Zalo)

Khu vực Miền Nam

Call: 0345 177 768 / Chat Zalo zalo

Khu vực Miền Bắc

Call: 0384 988 968 / Chat Zalo zalo

Khu vực Miền Trung

Call: 0374 687 899 / Chat Zalo zalo

Dịch vụ kỹ thuật/Bảo hành

Call: 0348 957 778 / Chat Zalo zalo

Email liên hệ

Dịch vụ cung ứng sản phẩm

Vì sản phẩm đa dạng, nếu Quý khách chưa tìm được. Vui lòng liên hệ để được hỗ trợ.

Tư vấn lựa chọn hoặc chuyển đổi
Nhập khẩu thiết bị theo yêu cầu

dich-vu-sua-chua-bien-tan-thiet-bi-tu-dong-hoa