|  Product characteristics | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2; Number of analogue outputs: 1 | 
|  Measuring range [l/min] |  0.2…150 | 
|  Process connection |  G 1 DN25 flat seal | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Media |  conductive liquids; water; hydrous media | 
|  Note on media | |  conductivity: ≥ 20 µS/cm |  |  viscosity: < 70 mm²/s (40 °C) |  
  | 
|  Medium temperature [°C] |  -20…90 | 
|  Pressure rating [bar] |  16 | 
|  Pressure rating [Mpa] |  1.6 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…30 DC; (according to EN 50178 SELV/PELV) | 
|  Current consumption [mA] |  < 80 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  5 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2; Number of analogue outputs: 1 | 
|  Inputs | 
|---|
|  Inputs |  counter reset | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; analogue signal; pulse signal; IO-Link; frequency signal; (configurable) | 
|  Electrical design |  PNP/NPN | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2 | 
|  Permanent current rating of switching output DC [mA] |  100 | 
|  Number of analogue outputs |  1 | 
|  Analogue current output [mA] |  4…20; (scalable) | 
|  Max. load [Ω] |  500 | 
|  Pulse output |  flow rate meter | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Measuring range [l/min] |  0.2…150 | 
|  Display range [l/min] |  -180…180 | 
|  Resolution [l/min] |  0.1 | 
|  Set point SP [l/min] |  1…150 | 
|  Reset point rP [l/min] |  0.2…149.2 | 
|  Analogue start point ASP [l/min] |  0…120 | 
|  Analogue end point AEP [l/min] |  30…150 | 
|  Low flow cut-off LFC [l/min] |  0.2…7.5 | 
|  Frequency end point, FEP [l/min] |  30.2…150 | 
|  Frequency at the end point FRP [Hz] |  1…10000 | 
|  Volumetric flow quantity monitoring | 
|---|
|  Pulse length [s] |  0.002…2 | 
|  Pulse value |  0.001…99990000 I | 
|  Temperature monitoring | 
|---|
|  Measuring range [°C] |  -20…90 | 
|  Display range [°C] |  -42…112 | 
|  Resolution [°C] |  0.1 | 
|  Set point SP [°C] |  -19.6…90 | 
|  Reset point rP [°C] |  -20…89.6 | 
|  Analogue start point [°C] |  -20…68 | 
|  Analogue end point [°C] |  2…90 | 
|  In steps of [°C] |  0.1 | 
|  Accuracy / deviations | 
|---|
|  Flow monitoring | 
|---|
|  Accuracy (in the measuring range) |  ± (0,8 % MW + 0,2 % MEW) | 
|  Repeatability |  ± 0,2 % MEW | 
|  Temperature monitoring | 
|---|
|  Accuracy [K] |  ± 2,5 (Q > 5 % MEW) | 
|  Response times | 
|---|
|  Flow monitoring | 
|---|
|  Start-up delay [s] |  0…50 | 
|  Response time [s] |  < 0.25; (dAP = 0, T09) | 
|  Damping for the switching output dAP [s] |  0…5 | 
|  Temperature monitoring | 
|---|
|  Response time [s] |  15; (Q > 10 % MEW, T09) | 
|  Software / programming | 
|---|
|  Parameter setting options |  hysteresis / window; normally open / normally closed; switching logic; frequency output; current/pulse output; start-up delay; display can be deactivated; Display unit | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 | 
|  Profiles |  Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  3 | 
|  Process data binary |  2 | 
|  Min. process cycle time [ms] |  6 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  961 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -20…60 | 
|  Storage temperature [°C] |  -25…80 | 
|  Protection |  IP 65; IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  787.5 | 
|  Materials |  stainless steel (1.4408/316); stainless steel (1.4404 / 316L); PC; PBT+PC-GF30 | 
|  Materials (wetted parts) |  stainless steel (1.4404 / 316L); PEEK; carbon fibre PEEK; EPDM; Centellen | 
|  Process connection |  G 1 DN25 flat seal | 
|  Displays / operating elements | 
|---|
|  Display |  |  colour display 1,44″, 128 x 128 pixels |   |  2 x LED, yellow |  
  | 
|  Remarks | 
|---|
|  Remarks | |  MW = measured value |  |  MEW = Final value of the measuring range |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |