| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range [ml/min] | 1…200 |
| Process connection | threaded connection G 1/8 |
| Application |
|---|
| Media | water; hydrous media |
| Medium temperature [°C] | 0…60 |
| Pressure rating [bar] | 10 |
| Electrical data |
|---|
| Operating voltage [V] | 19…30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] | < 110 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; pulse signal; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable) |
| Max. load [Ω] | 500 |
| Pulse output | consumed quantity meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Short-circuit proof | yes |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Measuring range [ml/min] | 1…200 |
| Display range [ml/min] | 0…240 |
| Set point SP [ml/min] | 6…200 |
| Reset point rP [ml/min] | 1…195 |
| Analogue start point ASP [ml/min] | 0…150 |
| Analogue end point AEP [ml/min] | 50…200 |
| In steps of [ml/min] | 1 |
| Measuring dynamics | 1:200 |
| Volumetric flow quantity monitoring |
|---|
| Pulse value | 0.1…2000000000 ml |
| In steps of | 0.1…1000000 ml |
| Pulse length [s] | 0,0125…2 |
| Temperature monitoring |
|---|
| Measuring range [°C] | 0…60 |
| Display range [°C] | 0…72 |
| Set point SP [°C] | 1.8…60 |
| Reset point rP [°C] | 0.3…58.5 |
| Analogue start point [°C] | 0…45 |
| Analogue end point [°C] | 15…60 |
| In steps of [°C] | 0.1 |
| Accuracy / deviations |
|---|
| Flow monitoring |
|---|
| Accuracy (in the measuring range) | ± (15 % MW + 2 % MEW); (The values apply for the following conditions:; Application: water; Medium temperature: 20 °C; Ambient temperature: 22…28 °C; unit with mounted flow conditioner) |
| Repeatability | ± 3% MW |
| Response times |
|---|
| Flow monitoring |
|---|
| Response time [s] | 0.3; (dAP = 0; for rising flow; for falling flow) |
| Damping for the switching output dAP [s] | 1…5 |
| Damping for the switching output dAP in steps [s] | 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1…5 |
| Software / programming |
|---|
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
| Operating conditions |
|---|
| Ambient temperature [°C] | 0…60 |
| Storage temperature [°C] | -25…85 |
| Protection | IP 65 |
| Mechanical data |
|---|
| Weight [g] | 453 |
| Materials | stainless steel (1.4404 / 316L); PC; PBT-GF20; POM; NBR |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); FKM |
| Process connection | threaded connection G 1/8 |
| Displays / operating elements |
|---|
| Display | | Display unit | 3 x LED, green (ml/min, ml, °C) | | function | 2 x LED, yellow | | switching status | 2 x LED, yellow | | measured values | alphanumeric display, 4-digit | | programming | alphanumeric display, 4-digit |
|
| Remarks |
|---|
| Remarks | | MW = measured value | | MEW = Final value of the measuring range | | Pressure drop without flow conditioner: max. 5 mbar. | | Pressure drop with flow conditioner: max. 23 mbar. |
|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12 |