Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Measuring range | |
Process connection | threaded connection G 1/2 sealing cone |
Installation length EL [mm] | 100 |
Application |
---|
Special feature | Gold-plated contacts |
Measuring element | 1 x Pt 1000 |
Reference element | 1 x NTC |
Media | liquids and gases |
Pressure rating [bar] | 160 |
Electrical data |
---|
Operating voltage [V] | 18…32 DC; (“supply class 2” to cULus) |
Current consumption [mA] | 10; (24 V) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 6 |
Integrated watchdog | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | analogue signal; IO-Link; calibration check status |
Electrical design | PNP/NPN |
Number of digital outputs | 1 |
Output function | normally open; (diagnostic signal) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 100 |
Diagnostic output | calibration check status and error diagnostics |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20 |
Max. load [Ω] | (Ub – 15 V) x 50 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | |
Note on measuring range | |
Factory setting | -10…150 °C / 14…302 °F |
Calibration check limit [K] | 0.5…3 |
In steps of [K] | 0.05 |
Resolution |
---|
Resolution of analogue output [K] | 0.05 |
Accuracy / deviations |
---|
Precision analogue output [K] | ± 0,2 |
Precision IO-Link [K] | ± 0,2 |
Temperature coefficient analogue output [% of the span / 10 K] | < ± 0,02; (in case of deviation from the reference condition 25 ± 5 °C) |
Temperature coefficient IO-Link [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) |
Response times |
---|
Dynamic response T05 / T09 [s] | 1,5 / 4 |
Software / programming |
---|
Parameter setting options | Display unit; scaling of the analogue output; calibration check limit; switching logic diagnostic output; simulation mode |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 CDV |
Profiles | Digital Measuring Sensor, Common Profile, Blob Transfer |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 1 |
Min. process cycle time [ms] | 4.4 |
IO-Link resolution temperature [K] | 0.01 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 1129 |
|
Operating conditions |
---|
Ambient temperature [°C] | -25…70 |
Note on ambient temperature | max. internal device temperature: 125 °C |
|
Storage temperature [°C] | -40…100 |
Protection | IP 68; IP 69K |
Mechanical data |
---|
Weight [g] | 457.3 |
Dimensions [mm] | Ø 50 / L = 194 |
Materials | stainless steel (1.4404 / 316L); PEI; FKM; PFA |
Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK |
Process connection | threaded connection G 1/2 sealing cone |
Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.8 |
Probe diameter [mm] | 6 |
Installation length EL [mm] | 100 |
Remarks |
---|
Remarks | MS = set measuring span | operating voltage “supply class 2” according to cULus |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |