Product characteristics |
---|
Electrical design | PNP |
Output function | normally open / normally closed; (parameterisable) |
Sensing range [mm] | 80…1200; (Target: 200 x 200 mm) |
Communication interface | IO-Link |
Housing | threaded type |
Dimensions [mm] | M18 x 1 / L = 60.5 |
Electrical data |
---|
Operating voltage [V] | 10…30 DC; (“supply class 2” to cULus) |
Current consumption [mA] | < 35 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 0.3 |
Converter frequency [kHz] | 200 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.2 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | 5 |
Short-circuit protection | yes |
Overload protection | yes |
Detection zone |
---|
Sensing range [mm] | 80…1200; (Target: 200 x 200 mm) |
Blind zone [mm] | 80 |
Angle of aperture cylindrical [°] | 14; (±2) |
Max. deviation from the 90° angle sensor/object [°] | ± 4 |
Accuracy / deviations |
---|
Temperature compensation | yes |
Hysteresis [%] | < 1 |
Switch point drift [%] | -2.5…2.5 |
Repeatability IO-Link [%] | < 0,7 |
Notes on the accuracy / deviation | The indicated values are reached after a warm-up time of min. 20 minutes |
Repeatability | 1 % |
Resolution [mm] | 1 |
Software / programming |
---|
Parameter setting options | hysteresis / window; second switch point; Switch-on and switch-off delay; switch-on operations; Teach function; light-on/dark-on mode |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Device Identification; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Process Data Variable; Device Diagnosis; Teach Channel |
SIO mode | yes |
Required master port type | A |
Min. process cycle time [ms] | 16 |
IO-Link process data (cyclical) | function | bit length | process value | 16 | device status | 4 | binary switching information | 2 |
|
IO-Link functions (acyclical) | application specific tag; operating hours counter |
Supported DeviceIDs | Type of operation | DeviceID | Default | 891 |
|
Note | For further information please see the IODD PDF file under “Downloads” |
|
Operating conditions |
---|
Ambient temperature [°C] | -20…70 |
Storage temperature [°C] | -30…80 |
Protection | IP 67 |
Mechanical data |
---|
Weight [g] | 79.8 |
Housing | threaded type |
Dimensions [mm] | M18 x 1 / L = 60.5 |
Thread designation | M18 x 1 |
Materials | stainless steel (1.4404 / 316L); PA; epoxy glass ceramics |
Tightening torque [Nm] | 50 |
Displays / operating elements |
---|
Display | switching status | 2 x LED, yellow | echo | 1 x LED, green |
|
Accessories |
---|
Accessories (supplied) | lock nuts: 2, stainless steel |
|
Remarks |
---|
Remarks | operating voltage “supply class 2” according to cULus |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12 |