|  Product characteristics | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2 | 
|  Measuring range |  | 
|  Process connection |  threaded connection G 3/4 DN20 | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Application |  for industrial applications | 
|  Media |  water | 
|  Medium temperature [°C] |  -10…90 | 
|  Pressure rating [bar] |  12 | 
|  Pressure rating [Mpa] |  1.2 | 
|  Note on pressure rating |  | 
|  MAWP (for applications according to CRN) [bar] |  4.3 | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…30 DC | 
|  Current consumption [mA] |  < 30 | 
|  Min. insulation resistance [MΩ] |  100; (500 V DC) | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  < 3 | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; frequency signal; IO-Link; (configurable) | 
|  Electrical design |  PNP/NPN | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2.5 | 
|  Permanent current rating of switching output DC [mA] |  100 | 
|  Short-circuit protection |  yes | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Measuring range |  | 
|  Display range |  | 
|  Resolution |  | 
|  Set point SP |  | 
|  Reset point rP |  | 
|  Frequency end point, FEP |  | 
|  In steps of |  | 
|  Frequency at the end point FRP [Hz] |  100…1000 | 
|  Measuring dynamics |  1:20 | 
|  Temperature monitoring | 
|---|
|  Measuring range [°C] |  -10…90 | 
|  Display range [°C] |  -30…110 | 
|  Resolution [°C] |  0.5 | 
|  Set point SP [°C] |  -9…90 | 
|  Reset point rP [°C] |  -10…89 | 
|  In steps of [°C] |  0.5 | 
|  Frequency start point, FSP [°C] |  -10…70 | 
|  Frequency end point, FEP [°C] |  10…90 | 
|  Frequency at the end point FRP [Hz] |  100…1000 | 
|  Accuracy / deviations | 
|---|
|  Flow monitoring | 
|---|
|  Accuracy (in the measuring range) |  ± 2 % MEW | 
|  Repeatability |  ± 0,5 % MEW | 
|  Temperature monitoring | 
|---|
|  Accuracy [K] |  ± 1 | 
|  Response times | 
|---|
|  Flow monitoring | 
|---|
|  Response time [s] |  1; (dAP = 0) | 
|  Damping for the switching output dAP [s] |  0…5 | 
|  Temperature monitoring | 
|---|
|  Dynamic response T05 / T09 [s] |  T09 = 6 | 
|  Software / programming | 
|---|
|  Parameter setting options |  hysteresis / window; normally open / normally closed; switching logic; frequency output; switch-on/switch-off delay; Damping; Display unit | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 | 
|  Profiles |  Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  2 | 
|  Process data binary |  2 | 
|  Min. process cycle time [ms] |  3 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  492 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  0…60 | 
|  Note on ambient temperature | |  medium temperature < 80 °C |  |  medium temperature < 90 °C: 0…50 °C |  
  | 
|  Storage temperature [°C] |  -20…80 | 
|  Protection |  IP 65; IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  508.8 | 
|  Materials |  stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U | 
|  Materials (wetted parts) |  stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM | 
|  Tightening torque [Nm] |  30 | 
|  Process connection |  threaded connection G 3/4 DN20 | 
|  Remarks | 
|---|
|  Remarks | |  MW = measured value |  |  MEW = Final value of the measuring range |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |