Cảm biến lưu lượng IFM SD0523 16 bar

SKU: SD0523
Hãng sản xuất: IFM
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

Báo giá
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.5…143.9 m/s 8…2110 m³/h 0.12…35.18 m³/min
Process connection threaded connection G 1 internal thread
Application
Installation Adjustable to inside pipe diameters; (38…254 mm)
Media compressed air
Medium temperature [°C] 0…60
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
Pressure rating [psi] 232
MAWP (for applications according to CRN) [bar] 16
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 110
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range Measuring/setting range; Flow monitoring; The values apply at: Ø 72 mm
Measuring range
0.5…143.9 m/s 8…2110 m³/h 0.12…35.18 m³/min
Display range
0…172.7 m/s 0…2532 m³/h 0…42.22 m³/min
Resolution
0.1 m/s 2 m³/h 0.02 m³/min
Set point SP
1.2…143.9 m/s 18…2110 m³/h 0.28…35.18 m³/min
Reset point rP
0.5…143.2 m/s 6…2100 m³/h 0.12…35 m³/min
Analogue start point ASP
0…107.9 m/s 0…1582 m³/h 0…26.38 m³/min
Analogue end point AEP
36…143.9 m/s 528…2110 m³/h 8.8…35.18 m³/min
In steps of
0.1 m/s 2 m³/h 0.02 m³/min
Volumetric flow quantity monitoring
Pulse value 1…1000 x 10³
In steps of 1 Nm³
Pulse length [s] 0,7…2 (D = 72 mm)
Temperature monitoring
Measuring range [°C] 0…60
Display range [°C] -12…72
Resolution [°C] 0.2
Set point SP [°C] 0.4…60
Reset point rP [°C] 0.2…59.8
Analogue start point [°C] 0…45
Analogue end point [°C] 15…60
In steps of [°C] 0.2
Accuracy / deviations
Flow monitoring
Repeatability [% of the measured value] ± 1,5
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); (D = 72mm, T = 22 °C; standard volume flow: 50…850 Nm³/h)
Temperature monitoring
Accuracy [K] ± 2,5 (Q > 2 Nm³/h)
Response times
Flow monitoring
Response time [s] 0.1; (dAP = 0)
Damping for the switching output dAP in steps [s] 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1
Temperature monitoring
Dynamic response T05 / T09 [s] 30 (Q > 2 Nm³/h)
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2
Min. process cycle time [ms] 5
Supported DeviceIDs
Type of operation DeviceID
Default 381
Operating conditions
Ambient temperature [°C] 0…60
Storage temperature [°C] -20…85
Max. relative air humidity [%] 90
Protection IP 65
Mechanical data
Weight [g] 442
Materials PBT-GF20; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts) stainless steel (1.4401 / 316); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM
Process connection threaded connection G 1 internal thread
Displays / operating elements
Display
Display unit 4 x LED, green (Nm³/min, Nm³/h, Nm³, °C)
function display 1 x LED, green
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
Remarks
Remarks
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
D = inside pipe diameter
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12

Thông tin bổ sung

Thương hiệu
Thời gian bảo hành

5 Năm

Điện áp ngõ vào
Ngõ ra

Analog, NC, NO, PNP

Yêu cầu tư vấn0983 995 440(Call/Zalo)

Cam kết và hỗ trợ

Luôn có giá tốt nhất thị trường
Giao hàng trên toàn quốc
Hỗ trợ dịch vụ kỹ thuật

Khu vực Miền Nam

Call: 0386 334 447 / Chat Zalo zalo

Khu vực Miền Bắc

Call: 0384 988 968 / Chat Zalo zalo

Khu vực Miền Trung

Call: 0374 687 899 / Chat Zalo zalo

Dịch vụ kỹ thuật/Bảo hành

Call: 0348 957 778 / Chat Zalo zalo

Email liên hệ

Dịch vụ cung ứng sản phẩm

Vì sản phẩm đa dạng, nếu Quý khách chưa tìm được. Vui lòng liên hệ để được hỗ trợ.

Tư vấn lựa chọn hoặc chuyển đổi
Nhập khẩu thiết bị theo yêu cầu

dich-vu-sua-chua-bien-tan-thiet-bi-tu-dong-hoa