Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection | threaded connection 1/2″ NPT DN15 |
Ar |
---|
Measuring range | 15…4310 scfh | 0.2…71.8 scfm | 2…552 sfs |
|
CO2 |
---|
Measuring range | 10…2640 scfh | 0.15…44 scfm | 1…338.5 sfs |
|
N2 |
---|
Measuring range | 10…2650 scfh | 0.15…44.15 scfm | 1…339.5 sfs |
|
Application |
---|
Application | for industrial applications |
Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
Medium temperature [°F] | 32…140 |
Pressure rating [bar] | 16 |
Pressure rating [psi] | 232 |
MAWP (for applications according to CRN) [bar] | 16 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | < 100 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 1 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Low flow cut-off LFC | < 46 scfh | < 0.76 scfm | 1…5.8 sfs |
|
Measuring dynamics | 1:300 |
Ar |
---|
Measuring range | 15…4310 scfh | 0.2…71.8 scfm | 2…552 sfs |
|
Display range | 0…5170 scfh | 0…86.2 scfm | 0…663 sfs |
|
Resolution | |
Set point SP | 40…4310 scfh | 0.7…71.8 scfm | 5…552 sfs |
|
Reset point rP | 20…4290 scfh | 0.4…71.5 scfm | 3…550 sfs |
|
Analogue start point ASP | 0…3445 scfh | 0…57.4 scfm | 0…442 sfs |
|
Analogue end point AEP | 860…4310 scfh | 14.4…71.8 scfm | 110…552 sfs |
|
In steps of | |
CO2 |
---|
Measuring range | 10…2640 scfh | 0.15…44 scfm | 1…338.5 sfs |
|
Display range | 0…3170 scfh | 0…52.8 scfm | 0…406 sfs |
|
Resolution | |
Set point SP | 25…2640 scfh | 0.4…44 scfm | 3…338.5 sfs |
|
Reset point rP | 15…2630 scfh | 0.2…43.8 scfm | 1.5…337 sfs |
|
Analogue start point ASP | 0…2110 scfh | 0…35.2 scfm | 0…271 sfs |
|
Analogue end point AEP | 530…2640 scfh | 8.8…44 scfm | 67.5…338.5 sfs |
|
In steps of | |
Volumetric flow quantity monitoring |
---|
Pulse value | 0.040…4 000 000 scf |
In steps of | 0.020…1000 scf |
Pulse length [s] | 0,007…2 |
N2 |
---|
Measuring range | 10…2650 scfh | 0.15…44.15 scfm | 1…339.5 sfs |
|
Display range | 0…3175 scfh | 0…52.95 scfm | 0…407.5 sfs |
|
Resolution | |
Set point SP | 25…2650 scfh | 0.4…44.15 scfm | 3…339.5 sfs |
|
Reset point rP | 15…2635 scfh | 0.2…43.95 scfm | 1.5…338 sfs |
|
Analogue start point ASP | 0…2120 scfh | 0…35.3 scfm | 0…271.5 sfs |
|
Analogue end point AEP | 530…2650 scfh | 8.85…44.15 scfm | 68…339.5 sfs |
|
In steps of | |
Temperature monitoring |
---|
Measuring range [°F] | 32…140 |
Display range [°F] | 10.5…161.5 |
Resolution [°F] | 0.5 |
Set point SP [°F] | 32.5…140 |
Reset point rP [°F] | 32…139.5 |
Analogue start point [°F] | 32…118.5 |
Analogue end point [°F] | 53.5…140 |
In steps of [°F] | 0.5 |
Accuracy / deviations |
---|
Flow monitoring |
---|
Repeatability [% of the measured value] | ± 1,5 |
Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
Temperature monitoring |
---|
Accuracy [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
Response times |
---|
Flow monitoring |
---|
Response time [s] | 0.1; (dAP = 0) |
Damping for the switching output dAP in steps [s] | 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1 |
Software / programming |
---|
Parameter setting options | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 3 |
Process data binary | 2 |
Min. process cycle time [ms] | 4.1 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 266 |
|
Operating conditions |
---|
Ambient temperature [°F] | 32…140 |
Storage temperature [°F] | -4…185 |
Max. relative air humidity [%] | 90 |
Protection | IP 65 |
Mechanical data |
---|
Weight [g] | 925.5 |
Materials | PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM |
Materials (wetted parts) | stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised |
Process connection | threaded connection 1/2″ NPT DN15 |
Displays / operating elements |
---|
Display | Display unit | 4 x LED, green (scfm, scfh, scf, °F) | function display | 1 x LED, yellow | switching status | 2 x LED, yellow | measured values | alphanumeric display, 4-digit | programming | alphanumeric display, 4-digit |
|
Display unit | scfm; scfh; scf; °F |
Remarks |
---|
Remarks | MW = measured value | MEW = Final value of the measuring range | Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12 |