Cảm biến lưu lượng IFM SD6101 16 bar

SKU: SD6101
Hãng sản xuất: IFM
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

Báo giá
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Process connection threaded connection 1/2″ NPT DN15
Ar
Measuring range
15…4310 scfh 0.2…71.8 scfm 2…552 sfs
CO2
Measuring range
10…2640 scfh 0.15…44 scfm 1…338.5 sfs
N2
Measuring range
10…2650 scfh 0.15…44.15 scfm 1…339.5 sfs
Application
Application for industrial applications
Media Argon (Ar); carbon dioxide (CO2); nitrogen (N2)
Medium temperature [°F] 32…140
Pressure rating [bar] 16
Pressure rating [psi] 232
MAWP (for applications according to CRN) [bar] 16
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Low flow cut-off LFC
< 46 scfh < 0.76 scfm 1…5.8 sfs
Measuring dynamics 1:300
Ar
Measuring range
15…4310 scfh 0.2…71.8 scfm 2…552 sfs
Display range
0…5170 scfh 0…86.2 scfm 0…663 sfs
Resolution
5 scfh 0.1 scfm 1 sfs
Set point SP
40…4310 scfh 0.7…71.8 scfm 5…552 sfs
Reset point rP
20…4290 scfh 0.4…71.5 scfm 3…550 sfs
Analogue start point ASP
0…3445 scfh 0…57.4 scfm 0…442 sfs
Analogue end point AEP
860…4310 scfh 14.4…71.8 scfm 110…552 sfs
In steps of
5 scfh 0.1 scfm 1 sfs
CO2
Measuring range
10…2640 scfh 0.15…44 scfm 1…338.5 sfs
Display range
0…3170 scfh 0…52.8 scfm 0…406 sfs
Resolution
5 scfh 0.05 scfm 0.5 sfs
Set point SP
25…2640 scfh 0.4…44 scfm 3…338.5 sfs
Reset point rP
15…2630 scfh 0.2…43.8 scfm 1.5…337 sfs
Analogue start point ASP
0…2110 scfh 0…35.2 scfm 0…271 sfs
Analogue end point AEP
530…2640 scfh 8.8…44 scfm 67.5…338.5 sfs
In steps of
5 scfh 0.05 scfm 0.5 sfs
Volumetric flow quantity monitoring
Pulse value 0.040…4 000 000 scf
In steps of 0.020…1000 scf
Pulse length [s] 0,007…2
N2
Measuring range
10…2650 scfh 0.15…44.15 scfm 1…339.5 sfs
Display range
0…3175 scfh 0…52.95 scfm 0…407.5 sfs
Resolution
5 scfh 0.05 scfm 0.5 sfs
Set point SP
25…2650 scfh 0.4…44.15 scfm 3…339.5 sfs
Reset point rP
15…2635 scfh 0.2…43.95 scfm 1.5…338 sfs
Analogue start point ASP
0…2120 scfh 0…35.3 scfm 0…271.5 sfs
Analogue end point AEP
530…2650 scfh 8.85…44.15 scfm 68…339.5 sfs
In steps of
5 scfh 0.05 scfm 0.5 sfs
Temperature monitoring
Measuring range [°F] 32…140
Display range [°F] 10.5…161.5
Resolution [°F] 0.5
Set point SP [°F] 32.5…140
Reset point rP [°F] 32…139.5
Analogue start point [°F] 32…118.5
Analogue end point [°F] 53.5…140
In steps of [°F] 0.5
Accuracy / deviations
Flow monitoring
Repeatability [% of the measured value] ± 1,5
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15)
Temperature monitoring
Accuracy [K] ± 2; (medium flow in the limit area of the flow measurement range)
Response times
Flow monitoring
Response time [s] 0.1; (dAP = 0)
Damping for the switching output dAP in steps [s] 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2
Min. process cycle time [ms] 4.1
Supported DeviceIDs
Type of operation DeviceID
Default 266
Operating conditions
Ambient temperature [°F] 32…140
Storage temperature [°F] -4…185
Max. relative air humidity [%] 90
Protection IP 65
Mechanical data
Weight [g] 925.5
Materials PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts) stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised
Process connection threaded connection 1/2″ NPT DN15
Displays / operating elements
Display
Display unit 4 x LED, green (scfm, scfh, scf, °F)
function display 1 x LED, yellow
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
Display unit scfm; scfh; scf; °F
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12

Thông tin bổ sung

Thương hiệu
Thời gian bảo hành

5 Năm

Điện áp ngõ vào
Ngõ ra

Analog, NC, NO, PNP

Yêu cầu tư vấn0342 678 887(Call/Zalo)

Khu vực Miền Nam

Call: 0345 177 768 / Chat Zalo zalo

Khu vực Miền Bắc

Call: 0384 988 968 / Chat Zalo zalo

Khu vực Miền Trung

Call: 0374 687 899/ Chat Zalo zalo

Dịch vụ kỹ thuật/Bảo hành

Call: 0348 957 778/ Chat Zalo zalo

Email liên hệ

dich-vu-sua-chua-bien-tan-thiet-bi-tu-dong-hoa