Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Measuring range | 30…7946 scfh | 1…132.4 scfm |
|
Process connection | threaded connection 1″ NPT DN25 |
Application |
---|
Application | for industrial applications |
Media | compressed air |
Note on media | air quality ISO 8573-1 | class 141 | class 344 |
|
Medium temperature [°F] | 32…140 |
Pressure rating [bar] | 16 |
Pressure rating [psi] | 232 |
MAWP (for applications according to CRN) [bar] | 16 |
Electrical data |
---|
Operating voltage [V] | 19…30 DC; (according to EN 50178 SELV/PELV) |
Current consumption [mA] | < 100 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 0.5 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; pulse signal; (configurable) |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250; (per output) |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (scalable) |
Max. load [Ω] | 500 |
Pulse output | consumed quantity meter |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | 30…7946 scfh | 1…132.4 scfm |
|
Display range | |
Set point SP | 70…7945 scfh | 1.2…132.4 scfm |
|
Reset point rP | 30…7905 scfh | 0.5…131.7 scfm |
|
Analogue start point ASP | |
Analogue end point AEP | 1985…7945 scfh | 33.1…132.4 scfm |
|
In steps of | |
Volumetric flow quantity monitoring |
---|
Pulse value | 0.120…4 000 000 scf |
In steps of | 0.020…1000 scf |
Pulse length [s] | 0,045…2 |
Temperature monitoring |
---|
Measuring range [°F] | 32…140 |
Display range [°F] | 32…140 |
Accuracy / deviations |
---|
Flow monitoring |
---|
Repeatability [% of the measured value] | ± 1,5 |
Accuracy (in the measuring range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 / ; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN25) |
Temperature monitoring |
---|
Accuracy [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
Response times |
---|
Flow monitoring |
---|
Response time [s] | 0.1; (dAP = 0) |
Damping for the switching output dAP in steps [s] | 0 – 0,2 – 0,4 – 0,6 – 0,8 – 1 |
Software / programming |
---|
Parameter setting options | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit |
Operating conditions |
---|
Ambient temperature [°F] | 32…140 |
Storage temperature [°F] | -4…185 |
Max. relative air humidity [%] | 90 |
Protection | IP 65 |
Mechanical data |
---|
Weight [g] | 1979.5 |
Materials | PBT-GF20; NBR; PC; stainless steel (1.4306 / 304L); PTFE; brass coated; aluminium powder-coated |
Materials (wetted parts) | stainless steel (1.4306 / 304L); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium |
Process connection | threaded connection 1″ NPT DN25 |
Displays / operating elements |
---|
Display | Display unit | 4 x LED, green (scfm, scfh, scf, °F) | function display | 1 x LED, yellow | switching status | 2 x LED, yellow | measured values | alphanumeric display, 4-digit | programming | alphanumeric display, 4-digit |
|
Remarks |
---|
Remarks | scf = standard cubic feet | scfh = standard cubic feet per hour | scfm = standard cubic feet per minute | MW = measured value | MEW = Final value of the measuring range | Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. | For information about installation and operation please see the operating instructions. |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12 |