| Product characteristics |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range [m³/h] | 58…17500 |
| Process connection | flange DN200 according to: DIN 2448 |
| Application |
|---|
| Application | totaliser function |
| Media | compressed air |
| Note on media | | air quality ISO 8573-1 | | class 141 | | class 344 |
|
| Medium temperature [°C] | 0…60 |
| Pressure rating [bar] | 16 |
| Pressure rating [Mpa] | 1.6 |
| Electrical data |
|---|
| Operating voltage [V] | 19…30 DC |
| Current consumption [mA] | < 100 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.5 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; pulse signal; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output [mA] | 4…20; (scalable) |
| Max. load [Ω] | 500 |
| Pulse output | consumed quantity meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Measuring range [m³/h] | 58…17500 |
| Display range [m³/h] | 0…21000 |
| Volumetric flow quantity monitoring |
|---|
| Pulse value | 10 Nm³ |
| Pulse length [s] | 0,1 |
| Accuracy / deviations |
|---|
| Flow monitoring |
|---|
| Accuracy (in the measuring range) | ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 / ; class 344) |
| Response times |
|---|
| Flow monitoring |
|---|
| Response time [s] | 0.1; (dAP = 0) |
| Operating conditions |
|---|
| Ambient temperature [°C] | 0…60 |
| Storage temperature [°C] | -20…85 |
| Max. relative air humidity [%] | 90 |
| Protection | IP 65 |
| Mechanical data |
|---|
| Weight [g] | 38500 |
| Materials | PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM; pipe section: steel galvanised |
| Materials (wetted parts) | stainless steel (1.4401 / 316); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised; steel galvanised |
| Process connection | flange DN200 according to: DIN 2448 |
| Remarks |
|---|
| Remarks | | MW = measured value | | MEW = Final value of the measuring range | | Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. | | For information about installation and operation please see the operating instructions. |
|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12 |