Cảm biến lưu lượng Keyence FD-H63F

Flow Sensors Hose model ø48–63
SKU: FD-H63F
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

Báo giá
ModelFD-H63F
TypeHose model
Supported pipe diameterø48–63 ø1.89″-2.48″
Supported pipe materialsSoft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1
Supported fluidsAll fluids (water, oil, chemicals, etc.)*1
Supported fluid temperature0–100°C 32–212°F (no freezing on pipe surface)*2
Maximum rated flow500 L/min132.1 gal/min
Zero cut flow rate5.0 L/min1.3 gal/min (variable, initial value)
Detection principleDelta TOF
Function for automatic correction for speed of sound in liquid
DisplayQVGA 2.0 model: color LCD, status indicator light
Display update cycleApprox. 10 times/second
Display resolutionInstantaneous flow0.01/0.1/1 (L/min) (default value: 1)
Integrated flow0.01/0.1/1 (L) (default value: 1; up to 8 digits)
Response time0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s
Measurement accuracy
Repeatability0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4
HysteresisVariable
Flow unitsL/min m3/h G/min
Pulse output increments (L)0.02–999.99
Pipe temperature measurement accuracy
Network supportIO-Link*5
Heat calculation functionUnitMJ/h kW kBTU/h*6
Display resolutionInstantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6
Pulse output increments (MJ)0.02–999.99*6
Data accumulationAccumulation periodApprox. 1 year
Data readingUSB2.0
Power I/O connectorM12 8-pin connector (male)
I/O (switchable)Output (Ch1/2/3/4)Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less
Analog output (Ch1/2)4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less
External input (Ch2/3)Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more
Power supplyPower voltage20–30 VDC, ripple (P-P) 10% included, Class 2/LPS
Current consumption240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7
Protection circuitProtection against reverse power connection, power supply surges, output short circuits, and output surges
Environmental resistanceEnclosure ratingIP65/67 (IEC 60529)*8
Ambient temperatureSensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2
Relative humidity35–85% RH (no condensation)
Vibration resistance10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions
Shock resistance100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes
MaterialDisplay unitBody: PPS/PET/POM; Display window: PAR
Sensor headBody: PPS/PET/PAR/SUS304; Cable: PVCSensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7
Weightapprox. 1360 g 47.97 oz
*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).*6 Can be used when two temperature sensors (sold separately) are connected.*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).*8 When a USB connection is in use, IP65/67 compliance is impaired.

Thông tin bổ sung

Thương hiệu
Thời gian bảo hành

1 Năm

Series
Yêu cầu tư vấn0983 995 440(Call/Zalo)

Có thể bạn thích…

Cam kết và hỗ trợ

Luôn có giá tốt nhất thị trường
Giao hàng trên toàn quốc
Hỗ trợ dịch vụ kỹ thuật

Khu vực Miền Nam

Call: 0386 334 447 / Chat Zalo zalo

Khu vực Miền Bắc

Call: 0384 988 968 / Chat Zalo zalo

Khu vực Miền Trung

Call: 0374 687 899 / Chat Zalo zalo

Dịch vụ kỹ thuật/Bảo hành

Call: 0348 957 778 / Chat Zalo zalo

Email liên hệ

Dịch vụ cung ứng sản phẩm

Vì sản phẩm đa dạng, nếu Quý khách chưa tìm được. Vui lòng liên hệ để được hỗ trợ.

Tư vấn lựa chọn hoặc chuyển đổi
Nhập khẩu thiết bị theo yêu cầu

dich-vu-sua-chua-bien-tan-thiet-bi-tu-dong-hoa