Model | KL-8BLT | |||
General specifications | Disconnection error output load | 30 VDC, 0.1 A or less, residual voltage: 1 V or less | ||
Vibration resistance | 10 to 55 Hz, 1.5 mm or less double amplitude for 2 hours in each of the X, Y, and Z directions; 1 G when attached to a DIN rail | |||
Insulation system | – | |||
Power voltage | 10.8 to 26.4 VDC (for the connector type I/O unit, this is supplied by the dedicated cable) | |||
Operating ambient temperature | 0 to 60°C | |||
Operating ambient humidity | 35 to 85%RH (no condensation) | |||
Operating environment | No corrosive gas present | |||
Noise immunity | Power supply common: 1,500 V, power supply normal: 500 V, pulse width: 1 ms, 50 ns (by way of a noise simulator) | |||
Withstand voltage | 500 VAC for 1 minute (between the power supply terminal and the I/O terminals; excluding the ERR output terminal) | |||
Insulation resistance | – | |||
Performance specifications | Input maximum rating | |||
Input voltage | ||||
Minimum ON voltage | ||||
Maximum OFF current | ||||
Maximum OFF voltage | ||||
Input impedance | ||||
Number of inputs/outputs | 8-terminal terminal block transistor output | |||
Internal current consumption | 80mA or less | |||
Weight | approx 130g | |||
Output specifications | Output | NPN open collector | ||
Residual voltage (when output is ON) | 0.8V or less | |||
Leakage current (when output is OFF) | 100 µA or less | |||
transistor output | Rated load voltage | 30 V DC and 5 to 26.4 V DC (power source supplied across VC and C) | ||
Rated output current | 0.5 A/output (when 24 V or more is applied across VC and C), 0.15 A/output (when 12 V or more is applied across VC and C), 0.05 A/output (when 5 V or more is applied across VC and C) | |||
Common ground | Written on the terminal wiring diagram of each unit | |||
ON delay time | 25 µs or less | |||
OFF delay time | 200 µs or less | |||
Insulation resistance | 20 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and the I/O terminals; excluding the ERR output terminal) | |||
Insulation system | Photocoupler isolation | |||
relay output | Rated voltage | – | ||
Rated output current | ||||
Common ground | ||||
ON resistance | ||||
ON delay time | ||||
OFF delay time | ||||
Insulation resistance | ||||
Insulation system |
Keyence KL-8BLT
Khối đầu cuối đinh vít 8 điểm, Ngõ ra Tranzito (bộ nhận), có chức năng bộ lặp
SKU: KL-8BLT
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: hóa đơn VAT
Dịch vụ kèm theo:
✓ Lập trình & Sửa chữa PLC Keyence theo yêu cầu
✓ Lắp đặt & vận hành tận nơi
✓ Hỗ trợ kỹ thuật trọn đời
✓ Lập trình & Sửa chữa PLC Keyence theo yêu cầu
✓ Lắp đặt & vận hành tận nơi
✓ Hỗ trợ kỹ thuật trọn đời
Thông tin bổ sung
Thương hiệu | |
---|---|
Thời gian bảo hành | 1 Năm |
Series | |
Yêu cầu tư vấn | 0342 678 887(Call/Zalo) |