ModelKL-LC1
General specificationsMeasurement typeLoad cell
Power voltage24 VDC ± 10%, Class 2
Operating ambient temperature0 to +50°C (no freezing)
Operating ambient humidity35 to 85%RH(no condensation)
Ambient temperature for storage-20 to +70°C
Operating environmentMinimal amount of dust and corrosive gas present
Measurement category
Wire temperature rating+60°C or more
Noise immunity1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator), conforms to IEC standards (IEC 61000-4-2/-3/-4/-6)
Withstand voltage1,500 VAC for 1 minute (between the power supply terminal and each terminal and between all the terminals and the case)
Insulation resistance100 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and each I/O terminal and between all the terminals and the case)
Internal current consumption (excluding current for driving input circuits)230mA or less
Shock resistanceConforms to JIS B 3502 and IEC 61131-2, 147 m/s2, operating time: 11 ms, 3 times in each of the 3 directions
Pollution degree2
Vibration resistanceIntermittent vibrationFrequency: 10 to 57 HzAmplitude: 0.075 mm*1
Frequency: 57 to 150 HzAcceleration: 9.8 m/s2*1
Continuous vibrationFrequency: 10 to 57 HzAmplitude: 0.035 mm*1
Frequency: 57 to 150 HzAcceleration: 4.9 m/s2*1
Weightapprox 350g
Performance specificationsNumber of channels1CH
Number of ranges4
Range switchingSetting: Use the setting switch.
Sampling rate1 ms (1,000 times/sec.)
Input range*2Range 1: 0.5 mV/V, range 2: 1.0 mV/V, range 3: 2.0 mV/V, range 4: 3.0 mV/V*2*3
Input range5VRange 1: 0.5 mV/V-2.5 to +2.5 mV*2*3
Range 2: 1.0 mV/V-5.0 to +5.0 mV*2*3
Range 3: 2.0 mV/V-10.0 to +10.0 mV*2*3
Range 4: 3.0 mV/V-15.0 to +15.0 mV*2*3
10 VRange 1: 0.5 mV/V-5.0 to +5.0 mV*2*3
Range 2: 1.0 mV/V-10.0 to +10.0 mV*2*3
Range 3: 2.0 mV/V-20.0 to +20.0 mV*2*3
Range 4: 3.0 mV/V-30.0 to +30.0 mV*2*3
Resolution5VRange 1: 0.5 mV/V0.5 µV, 1/10000
Range 2: 1.0 mV/V1.0 µV, 1/10000
Range 3: 2.0 mV/V2.0 µV, 1/10000
Range 4: 3.0 mV/V3.0 µV, 1/10000
10 VRange 1: 0.5 mV/V0.5 µV, 1/20000
Range 2: 1.0 mV/V1.0 µV, 1/20000
Range 3: 2.0 mV/V2.0 µV, 1/20000
Range 4: 3.0 mV/V3.0 µV, 1/20000
Linearity (0 to 50°C)±0.2% of F.S. ± 1 digit
Zero-drift (0 to 50°C)±0.4% of F.S. ± 1 digit
Control input2 (Parameters are used to switch between the KL input, peak/bottom hold control input, and 0-point adjustment input.)
Controloutput2 transistor (NPN open-collector) outputs (Parameters are used to switch between the KL output and comparator output.)
Setting dataRecorded to the EEPROM (rewritable 1,000,000 times)
Other functionsHold (peak and bottom), 0-point adjustment, comparator output, filter setting (LPF and HPF), time average (simple and moving), calibration setting (real and theoretical), display unit changing, lock
Compatible sensor350 Ω
Control I/O specificationsExternal calibration input signalNumber of inputs2
Maximum input voltageDC26.4V
Input rated voltageDC24V 5.3mA
Minimum ON voltage19V
Maximum OFF current1.5mA
Common ground2/common
Input time constant10ms
Control outputNumber of outputs2
OutputTransistor NPN output
Rated loadDC30V 0.1A
Peak load current0.2A
Leakage current (at OFF)100 µA or less
Residual voltage (at ON)DC0.8V or less
Common ground2/common
ON/OFF response timeOff to on: 10 µs or less (between 5 and 100 mA), on to off: 50 µs or less (between 5 and 100 mA)
KL link specificationsSupported master unitsModel: KL-N20V, supported PLC: KEYENCE KV-1000/700; model: KL-N10V, supported PLC: KEYENCE KV-10/16/24/40; model: KV-P16*L (built-in PLC), supported PLC: KEYENCE; model: KL-N20A, supported PLC: Mitsubishi AnA, AnA, AnU, QnA, AnSH, and Q2AS; model: KL-N20C, supported PLC: Omron C200H/HS, SYSMAC α, and CS1 (excluding the C200H-02/22), KEYENCE VT2-12F/10F/10T/10S/8T/8S/7S/5T/5S/5M and DT-100
Communication address00 H to FE H(0 to 254)
Number of occupied wordsEASY mode: reception (KL to PLC): 5 words, transmission (PLC to KL): 3 words; FULL mode: reception (KL to PLC): 7 words, transmission (PLC to KL): 5 words*4
Communication speed2.5 Mbps, 625 kbps, 156 kbps (set with parameters)*5
*1 Conforms to JIS B 3502, IEC61131-2
Number of sweeps: 10 times respectively in the X, Y, and Z directions (80 minutes)
*2 Select with the setting switch.
*3 If a signal that exceeds the input range has been entered, FFFF (-FFFF) will be displayed. Also, when calibration settings are in effect, if the measurement value exceeds the displayable range with signals in the input range, EFFF (-EFFF) will be displayed.
*4 In the direction of transmission/reception when seen from the master unit.
*5 The > do not support a communication speed of 5 Mbps.

Thông tin bổ sung

Thương hiệu
Thời gian bảo hành

1 Năm

Series
Yêu cầu tư vấn0342 678 887(Call/Zalo)

Khu vực Miền Nam

Call: 0345 177 768 / Chat Zalo zalo

Khu vực Miền Bắc

Call: 0384 988 968 / Chat Zalo zalo

Khu vực Miền Trung

Call: 0374 687 899/ Chat Zalo zalo

Dịch vụ kỹ thuật/Bảo hành

Call: 0348 957 778/ Chat Zalo zalo

Email liên hệ

dich-vu-sua-chua-bien-tan-thiet-bi-tu-dong-hoa