Technical
Connecting Capacity Auxiliary Circuit: | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm² Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm² Rigid Solid 1/2x 1 … 2.5 mm² Rigid Stranded 1/2x 1 … 2.5 mm² |
Maximum Electrical Switching Frequency: | 1200 cycles per hour |
Maximum Mechanical Switching Frequency: | 1800 cycles per hour |
Mechanical Durability: | 5 million |
Number of Auxiliary Contacts NC: | 2 |
Number of Auxiliary Contacts NO: | 0 |
Number of Poles: | 2 |
Rated Impulse Withstand Voltage (Uimp): | 6 kV |
Rated Insulation Voltage (Ui): | acc. to IEC 60947-5-1 690 V |
Standards: | IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1 |
Suitable For: | AF09 AF09Z AF12 AF12Z AF16 AF16Z AF26 AF26Z AF30 AF30Z AF38 AF38Z AFC09 AFC12 AFC16 AFC26 AFC30 AFC38 AF09B AF09ZB AF12B AF12ZB AF16B AF16ZB AF26B AF26ZB AF30B AF30ZB AF38B AF38ZB |
Terminal Type: | Screw Terminals |
Tightening Torque: | Auxiliary Circuit 1.2 N·m |
Wire Stripping Length: | Auxiliary Circuit 10 mm |
Dimensions
Product Net Width: | 25 mm |
Product Net Depth / Length: | 31.6 mm |
Product Net Height: | 43 mm |
Product Net Weight: | 0.035 kg |