| Product characteristics |
|---|
| Output function | normally closed |
| Sensing range [mm] | 3…15 |
| Housing | threaded type |
| Dimensions [mm] | M30 x 1.5 / L = 81 |
| Electrical data |
|---|
| Operating voltage [V] | 20…250 AC/DC |
| Protection class | II |
| Reverse polarity protection | no |
| Outputs |
|---|
| Output function | normally closed |
| Max. voltage drop switching output DC [V] | 8 |
| Max. voltage drop switching output AC [V] | 10 |
| Minimum load current [mA] | 5 |
| Max. leakage current [mA] | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
| Permanent current rating of switching output AC [mA] | 200; (for UL application: 200 / 100 DC) |
| Permanent current rating of switching output DC [mA] | 200; (for UL application: 200 AC / 100 DC) |
| Short-time current rating of switching output [mA] | 1500; (20 ms / 0,5 Hz) |
| Switching frequency AC [Hz] | 25 |
| Switching frequency DC [Hz] | 40 |
| Short-circuit proof | no |
| Overload protection | no |
| Detection zone |
|---|
| Sensing range [mm] | 3…15 |
| Sensing range adjustable | yes |
| Factory setting sensing range [mm] | 15 |
| Real sensing range Sr [mm] | 15 ± 10 % |
| Operating distance [mm] | 0…12.1 |
| Accuracy / deviations |
|---|
| Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
| Hysteresis [% of Sr] | 1…15 |
| Switch point drift [% of Sr] | -15…15 |
| Operating conditions |
|---|
| Ambient temperature [°C] | -25…70 |
| Protection | IP 65 |
| Increased immunity | yes; (increased immunity to conducted radio frequency interference) |
| Mechanical data |
|---|
| Weight [g] | 181 |
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions [mm] | M30 x 1.5 / L = 81 |
| Thread designation | M30 x 1.5 |
| Materials | PBT |
| Displays / operating elements |
|---|
| Display | | switching status | 1 x LED, red |
|
| Electrical connection |
|---|
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
| Accessories |
|---|
| Accessories (supplied) | | lock nuts: 2 | | screwdriver: 1 |
|
| Remarks |
|---|
| Remarks | | Recommendation: Check the safe functioning of the unit after a short circuit. |
|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Cable: 2 m, PVC; 2 x 0.5 mm² |