Product characteristics |
---|
Electrical design | factory setting: normally closed |
Output function | normally open / normally closed; (selectable) |
Sensing range [mm] | 3…15 |
Housing | threaded type |
Dimensions [mm] | M30 x 1.5 |
Electrical data |
---|
Operating voltage [V] | 20…250 AC/DC |
Protection class | I |
Reverse polarity protection | no |
Outputs |
---|
Electrical design | factory setting: normally closed |
Output function | normally open / normally closed; (selectable) |
Max. voltage drop switching output DC [V] | 8 |
Max. voltage drop switching output AC [V] | 10 |
Minimum load current [mA] | 5 |
Max. leakage current [mA] | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
Permanent current rating of switching output AC [mA] | 200; (250 (…50 °C)) |
Permanent current rating of switching output DC [mA] | 200; (250 (…50 °C)) |
Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) |
Switching frequency AC [Hz] | 25 |
Switching frequency DC [Hz] | 50 |
Short-circuit proof | no |
Overload protection | no |
Detection zone |
---|
Sensing range [mm] | 3…15 |
Sensing range adjustable | yes |
Factory setting sensing range [mm] | 15 |
Real sensing range Sr [mm] | 15 ± 10 % |
Operating distance [mm] | 0…12.1 |
Accuracy / deviations |
---|
Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
Hysteresis [% of Sr] | 1…15 |
Switch point drift [% of Sr] | -15…15 |
Operating conditions |
---|
Ambient temperature [°C] | -25…70 |
Protection | IP 65 |
Increased immunity | yes; (increased immunity to conducted radio frequency interference) |
Mechanical data |
---|
Weight [g] | 0.001 |
Housing | threaded type |
Mounting | non-flush mountable |
Dimensions [mm] | M30 x 1.5 |
Thread designation | M30 x 1.5 |
Materials | PBT; brass nickel-plated |
Displays / operating elements |
---|
Display | switching status | 1 x LED, red |
|
Accessories |
---|
Accessories (supplied) | lock nuts: 2 | screwdriver: 1 |
|
Remarks |
---|
Remarks | Recommendation: Check the safe functioning of the unit after a short circuit. |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
| Connector: 1 x 1/2″ |