|  Electrical data | 
|---|
|  Operating voltage [V] |  26.5…31.6 DC | 
|  Max. current consumption from AS-i [mA] |  280 | 
|  Integrated watchdog |  yes | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital inputs: 4; Number of pneumatic outputs: 2 | 
|  Inputs | 
|---|
|  Number of digital inputs |  4 | 
|  Input circuit of digital inputs |  PNP | 
|  Sensor supply of the inputs |  AS-i | 
|  Voltage supply [V] |  20…30; (via flat cable) | 
|  Max. total current rating of inputs [mA] |  200 | 
|  Input current High [mA] |  6…10 | 
|  Input current Low [mA] |  0…2 | 
|  Min. switching level high signal [V] |  11 | 
|  Digital inputs protected against short circuits |  yes | 
|  Outputs | 
|---|
|  Electrical design |  AS-i | 
|  Number of pneumatic outputs |  2 | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -10…50 | 
|  Protection |  IP 50 | 
|  AS-i classification | 
|---|
|  AS-i version |  2.11; 3.0 | 
|  AS-i addressing |  addressing socket | 
|  Extended addressing mode possible |  yes | 
|  AS-i profile |  S-7.A.E | 
|  AS-i I/O configuration [hex] |  7 | 
|  AS-i ID code [hex] |  A.E | 
|  AS-i certificate pending |  yes | 
|  Assignment of the data bits | |  data bit |  D0 |  D1 |  D2 |  D3 |  |  input |  1 |  2 |  3 |  4 |  |  socket |  I-1/2 |  I-1/2 I-2 |  I-3/4 |  I-3/4 I-4 |  |  pin |  4 |  2 4 |  4 |  2 4 |  |  pneumatic output |  2 |  4 |  – |  – |  
  | 
|  Mechanical data | 
|---|
|  Weight [g] |  421 | 
|  Type of mounting |  quick mounting | 
|  Materials |  PA; POM; piercing contacts: CuSn6 nickel-plated and tin-plated | 
|  Pneumatic system |  1 x 5/3-way slide valve (free from overlapping); middle position blocked | 
|  Operating pressure range [bar] |  3…8 | 
|  Operating pressure range [MPa] |  0.3…0.8 | 
|  Air flow at 6/5 bar [l/min] |  400 | 
|  Permissible compressed air |  non-lubricated compressed air class 6-3-1; lubricated compressed air class 6-3-4 | 
|  Manual override |  pressing/releasing or pressing/turning/locking | 
|  Tube fittings |  8 mm | 
|  Exhaust |  exhaust can be discharged through tube connection | 
|  Displays / operating elements | 
|---|
|  Display | |  operation |  LED, green |  |  errors |  LED, red |  |  function |  LED, yellow |  
  | 
|  Accessories | 
|---|
|  Accessories (supplied) |  | 
|  Accessories (optional) | |  Mounting plate:, E74999 |  |  Module lower part:, E75000 |  |  Protective cap: M12, E73004 |  |  sealing plugs:, E75231 |  |  Impact protection housing:, E7000A |  |  silencer:, E75232 |  |  Push-in L-fitting:, E75228 |  |  Push-in T-fitting:, E75227 |  
  | 
|  Remarks | 
|---|
|  Remarks | |  Mechanical protection has to be implemented. |  |  Otherwise the unit must be installed together with the impact protection housing (E7000A). |  |  If not pneumatically operated, E75231 sealing plug must be inserted. |  |  Avoid ingress of dirt and dust. |  |  Do not connect any of the following points to an external potential: |  |  L-, L+, I-1, I-2, I-3, I-4 |  |  The connections are electrically connected with the AS-i cable. |  |  Please see the notes on compressed air and EMC/ESD under “Downloads” |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  quick mounting technology for AS-i flat cable: ; three orientations possible | 
|  Connection |  Connector: M12 |