Product characteristics |
---|
Dimensions [mm] | 90 x 62 x 33.2 |
Inclination measurement |
---|
Number of measurement axes | 2 |
Application |
---|
Application | High-precision inclination measurement in 2 axes for mobile and industrial applications |
Electrical data |
---|
Operating voltage [V] | 9.2…30 DC; (voltage output: 12…30 DC; IO-Link: 18…30 DC) |
Current consumption [mA] | 90; (24 V DC, 25 °C) |
Max. current consumption [mA] | 330; (9,2 V DC; -40 °C) |
Protection class | III |
Reverse polarity protection | yes |
Reverse polarity protection | yes |
Max. initialisation time [ms] | 1000 |
Power-on delay time [s] | 300; (warm-up time) |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 2 |
Outputs |
---|
Total number of outputs | 4 |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (programmable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 125; (125 mA (85° C); 200 mA (60° C); 250 mA (40° C)) |
Number of analogue outputs | 2 |
Analogue current output [mA] | 4…20; (in case of a fault: 2 mA) |
Max. load [Ω] | 220; (220 (9,2…15 V) / 500 (15…30 V)) |
Analogue voltage output [V] | 2…10; (in case of a fault: 1 V) |
Min. load resistance [Ω] | 1000; (10000 (12…13,5 V) / 1000 (13,5…30 V)) |
Precision analogue output [%] | ≤ 1 |
Short-circuit protection | yes |
Overload protection | yes |
Measuring/setting range |
---|
Measuring principle | MEMS capacitive |
Inclination measurement |
---|
Number of measurement axes | 2 |
Angular range [°] | ± 180 |
Limit frequency [Hz] | 0.5…10; (parameterisable) |
Vibration measurement |
---|
Measuring range of vibration | 16; (± 2; ± 4; ±8 g parameterisable) g | 3200 mm/s |
|
Frequency range [Hz] | 0.1…400 |
Number of measurement axes | X/Y/Z parameterisable |
Accuracy / deviations |
---|
Accuracy [°] | ≤ ± 0,5 |
Repeatability [°] | ≤ ± 0,1 |
Resolution [°] | 0.05 |
Temperature coefficient [1/K] | ≤ ± 0,02 |
Software / programming |
---|
Parameter setting options | angle (X/Y) / vibration (Veff / aPeak); hysteresis / window; switch points; switching logic; fault indication; self-test; current/voltage output |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 CDV |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 2 |
Process data binary | 2 |
Min. process cycle time [ms] | 5 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 416 |
|
Operating conditions |
---|
Ambient temperature [°C] | -40…85 |
Storage temperature [°C] | -40…85 |
Protection | IP 65; IP 67; IP 68; IP 69K |
Mechanical data |
---|
Weight [g] | 410 |
Dimensions [mm] | 90 x 62 x 33.2 |
Materials | housing: diecast zinc nickel-plated |
Displays / operating elements |
---|
Display | operation | 1 x LED, green | switch point | 1 x LED, yellow |
|
Accessories |
---|
Accessories (supplied) | |
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection – digital |
---|
| Connector: 1 x M12 |
Electrical connection – analogue |
---|
| Connector: 1 x M12 |
Other data |
---|
Measuring/setting range |
---|
inclination measurement | | | | | | | | min. | max. | switch point | SP1 | [°] | -179.00 | 180.00 | reset point | rP1 | [°] | -180.00 | 179.00 | switch point | SP2 | [°] | -179.00 | 180.00 | reset point | rP2 | [°] | -180.00 | 179.00 | Analogue start point | ASP1 | [°] | -180.00 | 179.00 | Analogue end point | AEP1 | [°] | -179.00 | 180.00 | Analogue start point | ASP2 | [°] | -180.00 | 179.00 | Analogue end point | AEP2 | [°] | -179.00 | 180.00 | In steps of | | [°] | 0.01 | | | | | | | vibration measurement | | | | | | | | min. | max. | switch point | SP1 | [mm/s] | 1 | 3200 | reset point | rP1 | [mm/s] | 0 | 3199 | Analogue start point | ASP3 | [mm/s] | 0 | 3199 | Analogue end point | AEP3 | [mm/s] | 1 | 3200 | In steps of | | [mm/s] | 1 | | | | | | | vibration measurement | | | | | | | | min. | max. | switch point | SP2 | [mg] | 1 | 16000 | reset point | rP2 | [mg] | 0 | 15999 | Analogue start point | ASP4 | [mg] | 0 | 15999 | Analogue end point | AEP4 | [mg] | 1 | 16000 | In steps of | | [mg] | 1 | |
|