Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Factory setting | hydrous coolants; water; media similar to water |
Probe length L [mm] | 728 |
Application |
---|
Special feature | Gold-plated contacts |
Media | hydrous coolants; oils; oil-based media; water; media similar to water |
Dielectric constant of the medium | > 2 |
Cannot be used for | extremely conductive media; adhering media; granulates; bulk material; acids; alkali; hygienic areas and electroplating applications |
Maximum speed of the change of level [mm/s] | 300 |
Tank pressure [bar] | 0.5; (unpressurized for applications to WHG (German Federal Water Act)) |
Coolants |
---|
Medium temperature [°C] | 0…35; (with climatic tube E43102: 35…55 °C; not for applications to WHG (German Federal Water Act)) |
Oil |
---|
Medium temperature [°C] | 0…70 |
Medium temperature short time [°C] | 0…90; (< 1 h) |
Water |
---|
Medium temperature [°C] | 0…35; (with climatic tube E43102: 35…55 °C; not for applications to WHG (German Federal Water Act)) |
Electrical data |
---|
Operating voltage [V] | 12…30 DC |
Current consumption [mA] | < 50 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 3 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; IO-Link |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 200 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Factory setting | hydrous coolants; water; media similar to water |
Probe length L [mm] | 728 |
Active range A [mm] | 585 |
Inactive range I1 / I2 [mm] | 104 / 39 |
Setting range |
---|
Set point SP [mm] | 60…590 |
Reset point rP [mm] | 50…580 |
In steps of [mm] | 10 |
Reference point OP [mm] | 200 – 240 – 280 – 310 – 350 – 390 – 420 – 460 – 500 – 530 – 570 – 610 – OFF |
Hysteresis, OP [mm] | 4 |
Accuracy / deviations |
---|
Measuring error [% of the final value] | ± 5 |
Repeatability | ± 2 |
Resolution [mm] | 5 |
Software / programming |
---|
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 3 |
Process data binary | 2 |
Min. process cycle time [ms] | 3.2 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 804 |
|
Operating conditions |
---|
Ambient temperature [°C] | 0…60 |
Storage temperature [°C] | -25…80 |
Protection | IP 67 |
Mechanical data |
---|
Weight [g] | 706.4 |
Dimensions [mm] | Ø 16 |
Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV |
Materials (wetted parts) | PP |
Displays / operating elements |
---|
Display | Display unit | 2 x LED, green (cm, inch) | switching status | 2 x LED, yellow | measured values | alphanumeric display, 4-digit | parameter setting | alphanumeric display, 4-digit |
|
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |