|  Product characteristics | 
|---|
|  Output signal |  switching signal; IO-Link; (configurable) | 
|  Measuring range | |  0…250 bar |  0…3620 psi |  0…25 MPa |  
  | 
|  Process connection |  threaded connection G 1/4 external thread internal thread:M5 | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Measuring element |  metallic thin film cell | 
|  Application |  for industrial applications | 
|  Media |  liquids and gases | 
|  Medium temperature [°C] |  -25…80 | 
|  Min. bursting pressure | |  1100 bar |  15950 psi |  110 MPa |  
  | 
|  Pressure rating |  | 
|  Vacuum resistance [mbar] |  -1000 | 
|  Type of pressure |  relative pressure | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…30 DC; (according to EN 50178 SELV/PELV) | 
|  Current consumption [mA] |  < 35 | 
|  Min. insulation resistance [MΩ] |  100; (500 V DC) | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  0.3 | 
|  Integrated watchdog |  yes | 
|  Inputs / outputs | 
|---|
|  Number of inputs and outputs |  Number of digital outputs: 2 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; IO-Link; (configurable) | 
|  Electrical design |  PNP/NPN | 
|  Number of digital outputs |  2 | 
|  Output function |  normally open / normally closed; (parameterisable) | 
|  Max. voltage drop switching output DC [V] |  2.5 | 
|  Permanent current rating of switching output DC [mA] |  150; (200 (…60 °C) 250 (…40 °C)) | 
|  Switching frequency DC [Hz] |  < 170 | 
|  Short-circuit protection |  yes | 
|  Type of short-circuit protection |  pulsed | 
|  Overload protection |  yes | 
|  Measuring/setting range | 
|---|
|  Measuring range | |  0…250 bar |  0…3620 psi |  0…25 MPa |  
  | 
|  Factory setting / CMPT = 2 | 
|---|
|  Set point SP | |  2…250 bar |  40…3620 psi |  0.2…25 MPa |  
  | 
|  Reset point rP | |  1…249 bar |  20…3600 psi |  0.1…24.9 MPa |  
  | 
|  Min. difference between SP and rP |  | 
|  In steps of |  | 
|  Status_B High Resolution / CMPT = 3 | 
|---|
|  Set point SP | |  2…250 bar |  30…3626 psi |  0.2…25 MPa |  
  | 
|  Reset point rP | |  1…249 bar |  12…3608 psi |  0.1…24.9 MPa |  
  | 
|  Min. difference between SP and rP |  | 
|  In steps of |  | 
|  Accuracy / deviations | 
|---|
|  Switch point accuracy [% of the span] |  < ± 0,5 | 
|  Repeatability [% of the span] |  < ± 0,1; (with temperature fluctuations < 10 K) | 
|  Characteristics deviation [% of the span] |  < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | 
|  Hysteresis deviation [% of the span] |  < ± 0,25 | 
|  Long-term stability [% of the span] |  < ± 0,05; (per 6 months) | 
|  Temperature coefficient zero point [% of the span / 10 K] |  0,2; (-25…80 °C) | 
|  Temperature coefficient span [% of the span / 10 K] |  0,2; (-25…80 °C) | 
|  Response times | 
|---|
|  Response time [ms] |  < 3 | 
|  Delay time programmable dS, dr [s] |  0…50 | 
|  Software / programming | 
|---|
|  Parameter setting options |  hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 | 
|  SIO mode |  yes | 
|  Required master port type |  A; (when pin 2 not connected: B) | 
|  Process data analogue |  1 | 
|  Process data binary |  2 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Factory setting / CMPT = 2 |  400 |  |  Status_B High Resolution / CMPT = 3 |  598 |  |  PN7001 |  308 |  
  | 
|  Note | |  For further information please see the IODD PDF file under “Downloads” |  
  | 
|  Factory setting / CMPT = 2 | 
|---|
|  Profiles |  Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
|  Min. process cycle time [ms] |  2.3 | 
|  IO-Link resolution pressure [bar] |  1 | 
|  IO-Link resolution pressure [MPa] |  0.1 | 
|  IO-Link process data (cyclical) | |  function |  bit length |  |  pressure |  14 |  |  binary switching information |  2 |  
  | 
|  IO-Link functions (acyclical) |  application specific tag | 
|  Status_B High Resolution / CMPT = 3 | 
|---|
|  Profiles |  Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | 
|  Min. process cycle time [ms] |  3 | 
|  IO-Link resolution pressure [bar] |  0.1 | 
|  IO-Link resolution pressure [MPa] |  0.02 | 
|  IO-Link process data (cyclical) | |  function |  bit length |  |  pressure |  16 |  |  device status |  4 |  |  binary switching information |  2 |  
  | 
|  IO-Link functions (acyclical) |  application specific tag | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  -25…80 | 
|  Storage temperature [°C] |  -40…100 | 
|  Protection |  IP 65; IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  256 | 
|  Materials |  1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | 
|  Materials (wetted parts) |  1.4542 (17-4 PH / 630) | 
|  Min. pressure cycles |  100 million | 
|  Tightening torque [Nm] |  25…35; (recommended tightening torque; depends on lubrication, seal and pressure rating) | 
|  Process connection |  threaded connection G 1/4 external thread internal thread:M5 | 
|  Restrictor element integrated |  no (can be retrofitted) | 
|  Displays / operating elements | 
|---|
|  Display | |  Display unit |  3 x LED, green (bar, psi, MPa) |  |  switching status |  2 x LED, yellow |  |  measured values |  alphanumeric display, red/green 4-digit |  
  | 
|  Remarks | 
|---|
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |