Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection | threaded connection 1/2″ NPT |
Application |
---|
Special feature | Gold-plated contacts |
Media | water; glycol solutions; air; oils |
Note on media | low-viscosity oils with viscosity: ≤ 40 mm²/s (104 °F) | high-viscosity oils with viscosity: > 40 mm²/s (104 °F) |
|
Medium temperature [°F] | -4…194 |
Pressure rating [bar] | 100 |
Pressure rating [psi] | 1450 |
MAWP (for applications according to CRN) [bar] | 100 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC |
Current consumption [mA] | < 100 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 10 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 250 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4…20; (scalable) |
Max. load [Ω] | 350 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Frequency of the output [Hz] | 0…1000 |
Measuring/setting range |
---|
Probe length L [mm] | 26.6 |
Operating mode | relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) |
Note on factory setting | |
Liquids |
---|
Setting range [ft/s] | 0…19.5 |
Greatest sensitivity [ft/s] | 0.15…9.85 |
Gases |
---|
Setting range [ft/s] | 0…656 |
Greatest sensitivity [ft/s] | 6…328 |
Temperature monitoring |
---|
Measuring range [°F] | -4…194 |
Resolution [°F] | 0.5 |
Accuracy / deviations |
---|
Flow monitoring |
---|
Temperature drift [cm/s x 1/K] | 0,01 fps x 1/K (< 68 °F; > 158 °F) |
Temperature gradient [K/min] | 100 |
Accuracy | ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions :; water: 68…158 °F; inlet length: 5 ft; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
Repeatability | 0,05 m/s; (water; flow velocity: 0,05…3 m/s) |
Temperature monitoring |
---|
Temperature drift | ± 0,003 K/°F |
Accuracy [K] | ± 0,3 / ± 1; (water; flow velocity: 1…9,85 fps / air; flow velocity: > 32,8 fps) |
Response times |
---|
Flow monitoring |
---|
Response time [s] | 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
Temperature monitoring |
---|
Dynamic response T05 / T09 [s] | 1,5 (T09); (water; flow velocity: 1…9,85 fps) |
Software / programming |
---|
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port type | A |
Process data analogue | 2 |
Process data binary | 2 |
Min. process cycle time [ms] | 3 |
Supported DeviceIDs | Type of operation | DeviceID | Factory setting / ModE = (REL) | 537 | ModE = (LIQU) | 544 | ModE = (GAS) | 551 |
|
Operating conditions |
---|
Ambient temperature [°F] | -40…176 |
Storage temperature [°F] | -40…212 |
Protection | IP 65; IP 67 |
Mechanical data |
---|
Weight [g] | 277.5 |
Materials | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 |
Materials (wetted parts) | stainless steel (1.4404 / 316L) |
Process connection | threaded connection 1/2″ NPT |
Displays / operating elements |
---|
Display | Display unit | 6 x LED, green (%, fps, gpm, cfm, °F, 10³) | switching status | 2 x LED, yellow | measured values | alphanumeric display, red/green 4-digit |
|
Remarks |
---|
Remarks | MW = measured value | MEW = Final value of the measuring range |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |