|  Product characteristics | 
|---|
|  Process connection |  threaded connection G 3/4 internal thread | 
|  Temperature monitoring | 
|---|
|  Measuring range |  | 
|  Application | 
|---|
|  Special feature |  Gold-plated contacts | 
|  Media |  Liquids; oil | 
|  Note on media | |  oil with viscosity: 68 mm²/s (40 °C) |  
  | 
|  Medium temperature [°C] |  -10…100 | 
|  Pressure rating [bar] |  100 | 
|  Pressure rating [Mpa] |  10 | 
|  Note on pressure rating | |  at medium temperature >70°C: 80 bar / 8 MPa |  
  | 
|  Electrical data | 
|---|
|  Operating voltage [V] |  18…30 DC; (according to EN 50178 SELV/PELV) | 
|  Current consumption [mA] |  < 50 | 
|  Protection class |  III | 
|  Reverse polarity protection |  yes | 
|  Power-on delay time [s] |  < 3 | 
|  Outputs | 
|---|
|  Total number of outputs |  2 | 
|  Output signal |  switching signal; analogue signal; frequency signal; IO-Link | 
|  Max. voltage drop switching output DC [V] |  2 | 
|  Max. current load per output [mA] |  150; (200: …60 °C; Ambient temperature; 250: …40 °C; Ambient temperature) | 
|  Analogue current output [mA] |  4…20 | 
|  Max. load [Ω] |  500 | 
|  Short-circuit protection |  yes | 
|  Overload protection |  yes | 
|  Frequency of the output [Hz] |  0…10000 | 
|  Measuring/setting range | 
|---|
|  Measuring range | |  0.3…15 l/min |  0.018…0.9 m³/h |  4.8…237.8 gph |  0.08…3.965 gpm |  
  | 
|  Display range | |  0…18 l/min |  0…1.08 m³/h |  0…285.4 gph |  0…4.755 gpm |  
  | 
|  Resolution | |  0.01 l/min |  0.001 m³/h |  0.1 gph |  0.001 gpm |  
  | 
|  Set point SP | |  0.1…15 l/min |  0.006…0.9 m³/h |  1.6…237.8 gph |  0.025…3.965 gpm |  
  | 
|  Reset point rP | |  0…14.9 l/min |  0…0.894 m³/h |  0…236.2 gph |  0…3.935 gpm |  
  | 
|  Frequency end point, FEP | |  1…15 l/min |  0.06…0.9 m³/h |  15.8…237.8 gph |  0.265…3.965 gpm |  
  | 
|  In steps of | |  0.01 l/min |  0.001 m³/h |  0.2 gph |  0.005 gpm |  
  | 
|  Frequency at the end point FRP [Hz] |  10…10000 | 
|  In steps of [Hz] |  10 | 
|  Measuring dynamics |  1:50 | 
|  Temperature monitoring | 
|---|
|  Measuring range |  | 
|  Display range | |  -32…122 °C |  -25.6…251.6 °F |  
  | 
|  Resolution |  | 
|  Set point SP |  | 
|  Reset point rP |  | 
|  In steps of |  | 
|  Frequency start point, FSP |  | 
|  Frequency end point, FEP |  | 
|  Frequency at the end point FRP [Hz] |  10…10000 | 
|  Accuracy / deviations | 
|---|
|  Flow monitoring | 
|---|
|  Accuracy (in the measuring range) |  ± 5 % MEW; (Q > 1 l/min; 20…70 °C Medium temperature) | 
|  Repeatability |  ± 1 % MEW | 
|  Temperature monitoring | 
|---|
|  Temperature drift |  0,029 °C / K | 
|  Accuracy [K] |  3 K (25°C; Q > 1 l/min) | 
|  Response times | 
|---|
|  Flow monitoring | 
|---|
|  Response time [s] |  0.01 | 
|  Damping for the switching output dAP [s] |  0…5 | 
|  In steps of [s] |  0.1 | 
|  Damping for the analogue output dAA [s] |  0…5 | 
|  In steps of [s] |  0.1 | 
|  Temperature monitoring | 
|---|
|  Dynamic response T05 / T09 [s] |  T09 = 120 (Q > 1 l/min) | 
|  Software / programming | 
|---|
|  Parameter setting options |  hysteresis / window; normally open / normally closed; switching logic; current/frequency output; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour; calibration factor | 
|  Interfaces | 
|---|
|  Communication interface |  IO-Link | 
|  Transmission type |  COM2 (38,4 kBaud) | 
|  IO-Link revision |  1.1 | 
|  SDCI standard |  IEC 61131-9 CDV | 
|  Profiles |  Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | 
|  SIO mode |  yes | 
|  Required master port type |  A | 
|  Process data analogue |  2 | 
|  Process data binary |  2 | 
|  Min. process cycle time [ms] |  3.2 | 
|  Supported DeviceIDs | |  Type of operation |  DeviceID |  |  Default |  1043 |  
  | 
|  Operating conditions | 
|---|
|  Ambient temperature [°C] |  0…60 | 
|  Note on ambient temperature | |  medium temperature < 80 °C |  |  medium temperature < 100 °C: 0…40 °C |  
  | 
|  Storage temperature [°C] |  -15…80 | 
|  Protection |  IP 65; IP 67 | 
|  Mechanical data | 
|---|
|  Weight [g] |  994 | 
|  Materials |  stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated | 
|  Materials (wetted parts) |  stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM | 
|  Process connection |  threaded connection G 3/4 internal thread | 
|  Switching cycles mechanical |  10 million | 
|  Displays / operating elements | 
|---|
|  Display | |  Display unit |  6 x LED, green |  |  switching status |  2 x LED, yellow |  |  measured values |  alphanumeric display, red/green alternating indication 4-digit |  |  programming |  alphanumeric display, 4-digit |  
  | 
|  Remarks | 
|---|
|  Remarks | |  Recommendation: use a 200-micron filter. |  |  All data refer to oil with the following nominal viscosity: |  |  68 mm²/s, 40 °C |  |  MW = measured value |  |  MEW = Final value of the measuring range |  
  | 
|  Pack quantity |  1 pcs. | 
|  Electrical connection | 
|---|
|  Connection |  Connector: 1 x M12; Contacts: gold-plated |