| Product characteristics | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Process connection | threaded connection G 1/2 | 
| Temperature monitoring | 
|---|
| Measuring range [°C] | -10…100 | 
| Application | 
|---|
| Special feature | Gold-plated contacts | 
| Application | for industrial applications | 
| Media | water; glycol solutions; coolants; oil | 
| Note on media | | oil 1 with viscosity: 10 mm²/s (40 °C) |  | oil 2 with viscosity: 46 mm²/s (40 °C) | 
 | 
| Medium temperature [°C] | -10…100 | 
| Pressure rating [bar] | 40 | 
| Pressure rating [Mpa] | 4 | 
| MAWP (for applications according to CRN) [bar] | 40 | 
| Electrical data | 
|---|
| Operating voltage [V] | 18…30 DC; (according to EN 50178 SELV/PELV) | 
| Current consumption [mA] | < 50 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time [s] | < 3 | 
| Inputs / outputs | 
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | 
| Outputs | 
|---|
| Total number of outputs | 2 | 
| Output signal | switching signal; analogue signal; frequency signal; IO-Link; (configurable) | 
| Number of digital outputs | 2 | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC [V] | 2 | 
| Permanent current rating of switching output DC [mA] | 150; (per output 2 x 200 (…60 °C); 2 x 250 (…40 °C)) | 
| Switching cycles (mechanical) | 10 million | 
| Number of analogue outputs | 1 | 
| Analogue current output [mA] | 4…20 | 
| Max. load [Ω] | 500 | 
| Short-circuit protection | yes | 
| Overload protection | yes | 
| Frequency of the output [Hz] | 0…10000 | 
| Measuring/setting range | 
|---|
| Measuring range |  | 
| Display range |  | 
| Resolution |  | 
| Set point SP |  | 
| Reset point rP |  | 
| Frequency end point, FEP |  | 
| In steps of |  | 
| Frequency at the end point FRP [Hz] | 10…10000 | 
| Measuring dynamics | 1:50 | 
| Temperature monitoring | 
|---|
| Measuring range [°C] | -10…100 | 
| Display range [°C] | -32…122 | 
| Resolution [°C] | 1 | 
| Set point SP [°C] | -9…100 | 
| Reset point rP [°C] | -10…99 | 
| In steps of [°C] | 1 | 
| Frequency start point, FSP [°C] | -10…78 | 
| Frequency end point, FEP [°C] | 12…100 | 
| Frequency at the end point FRP [Hz] | 10…10000 | 
| Accuracy / deviations | 
|---|
| Flow monitoring | 
|---|
| Accuracy (in the measuring range) | ± (4 % MW + 1 % MEW); (Q > 1 l/min; medium and operating temperature: +22 °C ± 4K) | 
| Repeatability | ± 1 % MEW | 
| Temperature monitoring | 
|---|
| Temperature drift | 0,029 °C / K | 
| Accuracy [K] | 3 K (25°C; Q > 1 l/min) | 
| Response times | 
|---|
| Flow monitoring | 
|---|
| Response time [s] | 0.01 | 
| Damping for the switching output dAP [s] | 0…5 | 
| Damping for the analogue output dAA [s] | 0…5 | 
| Temperature monitoring | 
|---|
| Dynamic response T05 / T09 [s] | T09 = 120 (Q > 1 l/min) | 
| Software / programming | 
|---|
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour | 
| Interfaces | 
|---|
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.1 | 
| SDCI standard | IEC 61131-9 CDV | 
| Profiles | Smart Sensor: Process Data Variable; Device Identification | 
| SIO mode | yes | 
| Required master port type | A | 
| Process data analogue | 2 | 
| Process data binary | 2 | 
| Min. process cycle time [ms] | 5 | 
| Supported DeviceIDs | | Type of operation | DeviceID |  | Default | 562 | 
 | 
| Operating conditions | 
|---|
| Ambient temperature [°C] | 0…60 | 
| Note on ambient temperature | | medium temperature < 80 °C |  | medium temperature < 100 °C: 0…40 °C | 
 | 
| Storage temperature [°C] | -15…80 | 
| Protection | IP 65; IP 67 | 
| Mechanical data | 
|---|
| Weight [g] | 753.5 | 
| Materials | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated | 
| Materials (wetted parts) | stainless steel (1.4401 / 316); stainless steel (1.4404 / 316L); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM | 
| Process connection | threaded connection G 1/2 | 
| Displays / operating elements | 
|---|
| Display | | Display unit | 3 x LED, green |  | switching status | 2 x LED, yellow |  | measured values | alphanumeric display, red/green 4-digit |  | programming | alphanumeric display, 4-digit | 
 | 
| Remarks | 
|---|
| Remarks | | Recommendation: use a 200-micron filter. |  | All data refer to water (20 °C). |  | MW = measured value |  | MEW = Final value of the measuring range | 
 | 
| Pack quantity | 1 pcs. | 
| Electrical connection | 
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |