Primary brand | Mitsubishi Electric |
Main function | AC servo drive |
Product series / family name | MELSERVO J4 series |
Sub-range name | MR-J4 series |
Functions | AC motion servo drive / amplifiersine wave PWM control/current control method2-channel analog monitorSafe torque off (STO)fully closed loop controlload-side encoder interfaceadvanced vibration suppression control IIadaptive filter IIrobust filterauto tuningone-touch tuningtough drive functiondrive recorder functiontightening & press-fit functionmachine diagnosis functionpower monitoring functioncontroller-peripheral operation Function scale measurement functionJ3 compatibility modesuper trace controllost motion compensation |
Design | built-in dynamic brakebuilt-in regenerative resistorsafety unit compatibility2-wire or 4-wire type communication methodforced ventilation coolingSSCNET III/H |
Supply voltage (AC) | 200Vac-240Vac (200V class; 220Vac / 230Vac) |
Supply voltage (DC) | 283Vdc-340Vdc |
Type of network | Single-phase input (2P) or 3-phase input (3P) or DC input |
Rated current | 37A |
Rated active power (kW) | 7000W / 7kW |
Protection functions | overcurrent shut-offregenerative overvoltage shut-offoverload shut-off (electronic thermal)servo motor overheat protectionencoder fault protectionregenerative fault protectionundervoltage protectioninstantaneous power failure protectionoverspeed protectionexcessive error protectionmagnetic pole detection protectionlinear servo control fault protection |
Communication protocol | CC-Link |
Net Height (mm) | 300 mm |
Net Width (mm) | 172 mm |
Net Depth (mm) | 200 mm |
Digital inputs | 1 x digital input (24Vdc; sink/source) (EM2)1 x digital input (24Vdc; sink/source) (FLS)1 x digital input (24Vdc; sink/source) (RLS)1 x digital input (24Vdc; sink/source) (DOG) |
Digital outputs | 1 x digital output (rly. contact type) (ALM)1 x digital relay output (MBR)1 x digital output (rly. contact type) (INP) |
Analog outputs | 1 x analog output (-10…+10Vdc) (MO1)1 x analog output (-10…+10Vdc) (MO2) |
Degree of protection | IP20 |
Dimensions | H300mm x W172mm x D200mm |
Ambient air temperature for operation | 0…+55 °C |
Ambient air temperature for storage | -20°C…+65 °C |
Current consumption | 28.9A input |
Power consumption(drive auxiliary power consumption) | 45 W |
Order code / Manufacturer SKU | MR-J4-700B-RJ010 |
Manufacturer product status | Commercialized |
Equivalent to | MRJ4700BRJ010 |
Compliant with standard(s) | CE markingTUV RheinlandcULusULKCEN61800-5-2EN61800-5-1EN61800-3EN ISO 13849-1 PLe Cat3EN62061SILCL3IEC61508-5-2EN50581UL508CCSAKCEAC |
Benefits | high-speed serial communicationA/B/Z-phase differential input signal |
Recommended accessoriescompatible with servo motors | HG-JR503 (27A)HG-SR702 (26A)HG-JR703 (34A)HG-JR601 (31A)HG-JR701M (34A)HG-JR503W0C (27A)HG-SR702W0C (26A)HG-JR703W0C (34A)HG-JR701MW0C (34A)LM-FP2F-18M-1SS0 (12A (Natural cooling))LM-FP4D-24M-1SS0 (15A (Natural cooling)) |
[table “725” not found /]
Mitsubishi MR-J4
Models | Công suất | Điện áp cấp | Motor thường dùng |
---|---|---|---|
MR-J4-10A | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR13, HG-KR13B |
MR-J4-20A | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-40A | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-60A | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-70A | 0.75kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-100A | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-200A | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-350A | 3.5kW | 1 Pha / 3 Pha 220V | HG-SR301, HG-SR352 |
MR-J4-500A | 5kW | 1 Pha / 3 Pha 220V | HG-SR421, HG-SR502 |
MR-J4-700A | 7kW | 1 Pha / 3 Pha 220V | HG-SR702 |
MR-J4-10B | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR13, HG-KR13B |
MR-J4-20B | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-40B | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-60B | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-70B | 0.75kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-100B | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-200B | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-350B | 3.5kW | 1 Pha / 3 Pha 220V | HG-SR301, HG-SR352 |
MR-J4-500B | 5kW | 1 Pha / 3 Pha 220V | HG-SR421, HG-SR502 |
MR-J4-700B | 7kW | 1 Pha / 3 Pha 220V | HG-SR702 |
MR-J4-10A-RJ | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR053, HG-KR013, HG-MR053, HG-MR013 |
MR-J4-10B-RJ | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR053, HG-KR013, HG-MR053, HG-MR013 |
MR-J4-10B-RJ010 | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR053, HG-KR013, HG-MR053, HG-MR013 |
MR-J4-10B-RJ020 | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR053, HG-KR013, HG-MR053, HG-MR013 |
MR-J4-10GF-RJ | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR053, HG-KR013, HG-MR053, HG-MR013 |
MR-J4-10TM-ECT | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR053, HG-KR013, HG-MR053, HG-MR013 |
MR-J4-10TM-EIP | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR053, HG-KR013, HG-MR053, HG-MR013 |
MR-J4-10TM-PNT | 0.1kW | 1 Pha / 3 Pha 220V | HG-KR053, HG-KR013, HG-MR053, HG-MR013 |
MR-J4-20A-RJ | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-20B-RJ | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-20B-RJ010 | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-20B-RJ020 | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-20GF-RJ | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-20TM-ECT | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-20TM-EIP | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-20TM-PNT | 0.2kW | 1 Pha / 3 Pha 220V | HG-KR23, HG-MR23 |
MR-J4-40A-RJ | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-40B-RJ | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-40B-RJ010 | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-40B-RJ020 | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-40GF-RJ | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-40TM-ECT | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-40TM-EIP | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-40TM-PNT | 0.4kW | 1 Pha / 3 Pha 220V | HG-KR43, HG-MR43 |
MR-J4-60A-RJ | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-60A4-RJ | 0.6kW | 3 Pha 380V | HG-SR51, HG-SR52 |
MR-J4-60B-RJ | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-60B-RJ010 | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-60B-RJ020 | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-60B4-RJ | 0.6kW | 3 Pha 380V | HG-SR51, HG-SR52 |
MR-J4-60B4-RJ020 | 0.6kW | 3 Pha 380V | HG-SR51, HG-SR52 |
MR-J4-60GF-RJ | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-60GF4-RJ | 0.6kW | 3 Pha 380V | HG-SR51, HG-SR52 |
MR-J4-60TM-ECT | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-60TM-EIP | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-60TM-PNT | 0.6kW | 1 Pha / 3 Pha 220V | HG-SR51, HG-SR52 |
MR-J4-60TM4-ECT | 0.6kW | 3 Pha 380V | HG-SR51, HG-SR52 |
MR-J4-60TM4-EIP | 0.6kW | 3 Pha 380V | HG-SR51, HG-SR52 |
MR-J4-60TM4-PNT | 0.6kW | 3 Pha 380V | HG-SR51, HG-SR52 |
MR-J4-70A-RJ | 0.75kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-70B-RJ | 0.75kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-70B-RJ010 | 0.75kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-70B-RJ020 | 0.75kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-70GF-RJ | 0.7kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-70TM-ECT | 0.7kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-70TM-EIP | 0.7kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-70TM-PNT | 0.7kW | 1 Pha / 3 Pha 220V | HG-KR73, HG-MR73 |
MR-J4-11KA4-RJ | 11kW | 3 Pha 380V | HG-JR9034, HG-JR8014, HG-JR12K14, HG-JR11K1M4 |
MR-J4-11KB4-RJ | 11kW | 3 Pha 380V | HG-JR9034, HG-JR8014, HG-JR12K14, HG-JR11K1M4 |
MR-J4-11KTM-EIP | 11kW | 1 Pha / 3 Pha 220V | HG-JR9034, HG-JR8014, HG-JR12K14, HG-JR11K1M4 |
MR-J4-11KTM-PNT | 11kW | 1 Pha / 3 Pha 220V | HG-JR9034, HG-JR8014, HG-JR12K14, HG-JR11K1M4 |
MR-J4-11KTM4-EIP | 11kW | 3 Pha 380V | HG-JR9034, HG-JR8014, HG-JR12K14, HG-JR11K1M4 |
MR-J4-11KTM4-PNT | 11kW | 3 Pha 380V | HG-JR9034, HG-JR8014, HG-JR12K14, HG-JR11K1M4 |
MR-J4-15KA4-RJ | 15kW | 3 Pha 380V | HG-JR15K14 |
MR-J4-15KB4-RJ | 15kW | 3 Pha 380V | HG-JR15K14 |
MR-J4-15KTM-EIP | 15kW | 1 Pha / 3 Pha 220V | HG-JR15K14 |
MR-J4-15KTM-PNT | 15kW | 1 Pha / 3 Pha 220V | HG-JR15K14 |
MR-J4-15KTM4-EIP | 15kW | 3 Pha 380V | HG-JR15K14 |
MR-J4-15KTM4-PNT | 15kW | 3 Pha 380V | HG-JR15K14 |
MR-J4-100A-RJ | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-100A4-RJ | 1kW | 3 Pha 380V | HG-SR81, HG-SR102 |
MR-J4-100B-RJ | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-100B-RJ010 | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-100B-RJ020 | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-100B4-RJ | 1kW | 3 Pha 380V | HG-SR81, HG-SR102 |
MR-J4-100B4-RJ020 | 1kW | 3 Pha 380V | HG-SR81, HG-SR102 |
MR-J4-100GF-RJ | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-100GF4-RJ | 1kW | 3 Pha 380V | HG-SR81, HG-SR102 |
MR-J4-100TM-ECT | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-100TM-EIP | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-100TM-PNT | 1kW | 1 Pha / 3 Pha 220V | HG-SR81, HG-SR102 |
MR-J4-100TM4-ECT | 1kW | 3 Pha 380V | HG-SR81, HG-SR102 |
MR-J4-100TM4-EIP | 1kW | 3 Pha 380V | HG-SR81, HG-SR102 |
MR-J4-100TM4-PNT | 1kW | 3 Pha 380V | HG-SR81, HG-SR102 |
MR-J4-22KA4-RJ | 22kW | 3 Pha 380V | HG-JR20K14, HG-JR25K14, HG-JR22K1M4 |
MR-J4-22KB4-RJ | 22kW | 3 Pha 380V | HG-JR20K14, HG-JR25K14, HG-JR22K1M4 |
MR-J4-22KTM-EIP | 22kW | 1 Pha / 3 Pha 220V | HG-JR20K14, HG-JR25K14, HG-JR22K1M4 |
MR-J4-22KTM-PNT | 22kW | 1 Pha / 3 Pha 220V | HG-JR20K14, HG-JR25K14, HG-JR22K1M4 |
MR-J4-22KTM4-EIP | 22kW | 3 Pha 380V | HG-JR20K14, HG-JR25K14, HG-JR22K1M4 |
MR-J4-22KTM4-PNT | 22kW | 3 Pha 380V | HG-JR20K14, HG-JR25K14, HG-JR22K1M4 |
MR-J4-200A-RJ | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200A4-RJ | 2kW | 3 Pha 380V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200B-RJ | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200B-RJ010 | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200B-RJ020 | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200B4-RJ | 2kW | 3 Pha 380V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200B4-RJ020 | 2kW | 3 Pha 380V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200GF-RJ | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200GF4-RJ | 2kW | 3 Pha 380V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200TM-ECT | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200TM-EIP | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200TM-PNT | 2kW | 1 Pha / 3 Pha 220V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200TM4-ECT | 2kW | 3 Pha 380V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200TM4-EIP | 2kW | 3 Pha 380V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-200TM4-PNT | 2kW | 3 Pha 380V | HG-SR121, HG-SR201, HG-SR152, HG-SR202 |
MR-J4-350A-RJ | 3.5kW | 1 Pha / 3 Pha 220V | HG-SR301, HG-SR352 |
MR-J4-350A4-RJ | 3.5kW | 3 Pha 380V | HG-SR301, HG-SR352 |
MR-J4-350B-RJ | 3.5kW | 1 Pha / 3 Pha 220V | HG-SR301, HG-SR352 |
MR-J4-350B-RJ010 | 3.5kW | 1 Pha / 3 Pha 220V | HG-SR301, HG-SR352 |
MR-J4-350B-RJ020 | 3.5kW | 1 Pha / 3 Pha 220V | HG-SR301, HG-SR352 |
Bảng hướng dẫn lựa chọn Servo Mitsubishi MR-J4 Series
Download tài liệu Servo Mitsubishi MR-J4 Series
► Catalogue Servo Mitsubishi MR-J4 Series