Product characteristics |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Probe length L [mm] | 100…1600 |
Process connection | G 3/4 external thread |
Application |
---|
Special feature | Gold-plated contacts |
Media | Liquids |
Dielectric constant of the medium | ≥ 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) |
Recommended media | water; hydrous media; oils; oil-based media |
Cannot be used for | See the operating instructions, chapter “Function and features”. |
Medium temperature [°C] | -25…80; (90 < 1 h) |
Tank pressure [bar] | -1…16 |
MAWP (for applications according to CRN) [bar] | 16 |
Electrical data |
---|
Operating voltage [V] | 18…30 DC |
Current consumption [mA] | < 30 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 3 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal; IO-Link |
Electrical design | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 200 |
Short-circuit protection | yes |
Type of short-circuit protection | thermal, pulsed |
Overload protection | yes |
Measuring/setting range |
---|
Probe length L [mm] | 100…1600 |
Active range A [mm] | L-40; (when set to oil and oil based media: L-60) |
Inactive range I1 / I2 [mm] | 30 / 10; (when set to oil and oil based media: 30 / 30) |
Sampling rate [Hz] | 4 |
Setting range |
---|
Set point SP [mm] | ≥ 15…L-30 |
Note on setpoint SP | when set to oil and oil based media: 35…L-30 |
|
Reset point rP [mm] | ≥ 10…L-35 |
Note on reset point rP | when set to oil and oil based media: 30…L-35 |
|
In steps of [mm] | 5 |
Hysteresis [mm] | > 5 |
Accuracy / deviations |
---|
Repeatability [mm] | ± 5 |
Measuring error [mm] | ± 7 |
Offset error [mm] | 5 |
Resolution [mm] | 1 |
Temperature drift per 10 K | ± 0.2 % |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 CDV |
Profiles | no profile |
SIO mode | yes |
Required master port type | A |
Process data analogue | 1 |
Process data binary | 2 |
Min. process cycle time [ms] | 2.3 |
Supported DeviceIDs | Type of operation | DeviceID | Default | 8 |
|
Operating conditions |
---|
Ambient temperature [°C] | -25…60 |
Storage temperature [°C] | -40…85 |
Protection | IP 67 |
Mechanical data |
---|
Weight [g] | 444.4 |
Materials | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V |
Materials (wetted parts) | stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre |
Process connection | G 3/4 external thread |
Displays / operating elements |
---|
Display | Display unit | 3 x LED, green | switching status | 2 x LED, yellow | level | alphanumeric display, 4-digit | parameter setting | alphanumeric display, 4-digit |
|
Remarks |
---|
Notes | Please see the technical note under “Downloads” |
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |